Heartbeat detection and personal authentication using a 60 GHz Doppler sensor
Takuma Asano1, Shintaro Izumi1, Hiroshi Kawaguchi1
1Architecture Laboratory, Graduate School of Science, Technology and Innovation, Kobe University, Kobe, Japan.
Background:
Microwave Doppler sensors, capable of detecting minute physiological movements, enable the measurement of biometric information, such as walking patterns, heart rate, and respiration. Unlike fingerprint and facial recognition systems, they offer authentication without physical contact or privacy concerns. This study focuses on non-contact seismocardiography using microwave Doppler sensors and aims to apply this technology for biometric authentication.
Method:
We proposed a method for authenticating and identifying heartbeat signals through supervised learning using a conditional variational autoencoder (CVAE). A 60 GHz microwave Doppler sensor was used to capture heartbeat signals, which were processed using a conformer network to detect peaks and segment individual beats. High signal-to-noise ratio waveforms were selected, and time-frequency analysis extracted relevant features. Spectrograms labeled with subject data were input into the CVAE, which encoded subject-specific features into a latent space for authentication.
Results:
The proposed heartbeat-based authentication method, validated on 13 subjects, achieved an average balanced accuracy of 97.3% for authentication and an average accuracy of 94.7% for identification. Compared with conventional methods, this approach demonstrated superior performance by effectively encoding subject-specific features while mitigating noise-related challenges.
Conclusion:
The proposed method enhanced the feasibility of non-contact heartbeat-based authentication by achieving high accuracy while addressing noise-related challenges. Its application could improve biometric security without compromising user privacy. Further advancements in handling posture variations and scalability are essential for real-world implementation.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Doppler Effect - II
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring pulse
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...