A pilot study on the impact of wearing powered air-purifying respirators on speech intelligibility
Ikenna Orji1, Elizabeth L Beam2, Kelli R Kopocis3,4
1Department of Environmental Agricultural and Occupational Health, College of Public Health, University of Nebraska Medical Center, Omaha, Nebraska.
Abstract:
Powered air-purifying respirators (PAPR) have become an increasingly utilized form of respiratory protection against highly infectious aerosols. In the United States, PAPRs have been used in high-level clinical isolation settings to care for patients infected with viral hemorrhagic fevers and, more recently, during the COVID-19 pandemic. PAPRs have long been used for biocontainment care and experienced increased use during the pandemic because they provide full-face visibility and eye and respiratory protection. Despite their extended use, limited studies have explored the operational usability and limitations of these devices, especially during patient care and communication. For this pilot study, the speech intelligibility of two commonly used PAPR brands was examined in a clinical setting using some requirements from the National Institute for Occupational Safety and Health (NIOSH) standard testing procedure (NIOSH TEB-CBRN-APR-STP-0313 Determination of Communication Performance Test For Speech) for determining communication performance for speech conveyance in PAPRs. A total of 19 study participants were split into 17 speakers and two listeners. Speakers were assigned to test groups. Each speaker was provided with a word list, while listeners were provided with a response list. A modified rhyme test (MRT) was conducted to determine the communication performance rating of each PAPR brand. The 3M PAPR had a higher performance rating than MAXAIR across all test groups, despite having a 5 dBA higher internal noise. The difference in the mean performance rating of 3M (75) was significantly higher than that of MAXAIR (59) (95% CI: -23.66-9.09). Overall, the 3M PAPR was strongly preferred among study participants in terms of comfort, fit, and noise level. Interventions such as incorporating communication devices are of interest for future study, and an assessment of additional limitations is needed to optimize PAPR use in clinical care activities.
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...