Related Experiment Video
Updated: Jul 17, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Developing and validating a bi-polar gated respiratory motion management strategy for improved lung stereotactic body
Zhen Li1,2, Xueli Liu1, Libo Zhang3
1Department of Radiation Oncology, Fudan University Huadong Hospital, Shanghai 200040, China.
Background:
Stereotactic body radiotherapy (SBRT) is an effective treatment for early-stage non-small cell lung cancer. However, patient breathing can affect treatment accuracy. Therefore, this study aimed to develop a bi-polar (BP) gated motion management strategy for SBRT and evaluate its feasibility geometrically and dosimetrically.
Methods:
The BP strategy involved instructing patients to hold their breath briefly at the end of both inhalation (EI) and exhalation (EE), with radiation delivered only during these breath-holding periods. Eight volunteers were included to evaluate breathing stability, repeatability, and patient comfort. Additionally, 15 patients were retrospectively studied to evaluate the geometric and dosimetric efficiency of BP in intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) modes. BP plans were compared with four common breathing strategies: free breathing (FB), gating at the end of inhalation (GI), gating at the end of exhalation (GE), and real-time tracking (RT).
Results:
Volunteers could comfortably hold their breath for >3 minutes, demonstrating good stability and repeatability. Geometrically, the ratio of BP's internal target volume (ITV) to GI's ITV was the smallest at 0.65, compared to 1.89 for FB, 1.05 for GE, and 0.68 for RT. In the dosimetric evaluation of IMRT plans, the lung V20Gy ratio for BP to GI was the smallest at 0.89. Similar trends were observed for VMAT plans.
Conclusions:
The BP strategy is a feasible option for lung SBRT, offering reduced treatment volumes and normal tissue toxicity, with a high duty cycle and less technical complexity than other RT-based methods.
More Related Videos
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
COPD: Management Using Bronchodilators and Corticosteroids
Chronic Obstructive Pulmonary Disease-V: Management
Smoking Cessation
Chronic Obstructive Pulmonary Disease-V: Nursing Management
Assessment
Pneumothorax-II
Clinical Manifestations:
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Cardiopulmonary Resuscitation II: ACLS Airway Management