Related Experiment Video
Updated: Jan 18, 2026

Microdialysis of Ethanol During Operant Ethanol Self-administration and Ethanol Determination by Gas Chromatography
Published on: September 5, 2012
Determination of alcohol concentration in a single drop blood obtained via fingertip using gas chromatography/mass
Koichi Saito1, Tomonori Asanuma1, Rie Ito1
1Department of Analytical Chemistry, School of Pharmacy and Pharmaceutical Sciences, Hoshi University, 2-4-41, Ebara, Shinagawa-ku, Tokyo 142-8501, Japan.
Abstract:
This study investigated headspace solid-phase microextraction (HS-SPME)-gas chromatography (GS)/mass spectrometry as a low-complexity method for accurate measurement of blood alcohol concentration (BAC) changes in humans over time following alcohol consumption. The aim was to develop an analytical method that would require as small blood samples as possible-smaller than that required for the conventional method-thereby reducing the burden on the subject. Polyethylene glycol (PEG) was used as the fiber material for SPME, and a DB-WAX capillary column was used for GC. For sample extraction via SPME, 50 µL of blood sample obtained via fingertip puncture was added to a vial already containing 3 mL of 20 % aqueous sodium chloride solution, following which an SPME fiber was inserted into the vapor phase (headspace) of the vial and heated at 70 ℃ for 20 min to sorb ethanol onto the fiber. The experiment for ethanol recovery in whole blood yielded recoveries of 71.1 % when spiked at 100 µg/mL and 95.1 % when spiked at 1000 µg/mL. Blood samples were obtained periodically with consent from a human volunteer who had actually consumed alcohol, and the BAC was shown to decrease with a peak 1.5 h after drinking, confirming the applicability of this method in BAC assessment when compared with the conventional Widmark method. Furthermore, the applicability of this method was also investigated in the case of saliva, which can be collected more easily and non-invasively than blood.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Mass Spectrometry: Alcohol Fragmentation
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...

