A machine learning based dual-energy CT elemental decomposition method and its physical-biological impacts on carbon
Yan Li1,2, Weiguang Li1,2,3, Chao Yang2
1School of Physics, Beihang University, Beijing, China.
Background:
Dual-energy computed tomography (DECT) enhances material differentiation by leveraging energy-dependent attenuation properties particularly for carbon ion therapy. Accurate estimation of tissue elemental composition via DECT can improve quantification of physical and biological doses.
Objective:
This study proposed a novel machine-learning-based DECT (ML-DECT) method to predict the physical density and mass ratios of H, C, N, O, P, and Ca. The physical and biological impacts on carbon ion therapy was also investigated.
Methods:
Taking DECT-derived CT numbers as inputs, a fully connected neural network was employed to predict the physical density or the elemental mass ratio. The training and testing utilized a dataset of 85 biological tissues with data augmentation. The prediction accuracy and noise analysis were compared against the parameterization DECT (PA-DECT) and SECT methods. By applying the proposed method on the DECT images of 10 head-and-neck patients, the physical and biological doses as well as the linear energy transfer (LET) were calculated for a set of carbon ion pencil beams using Monte-Carlo simulations. Patient-based results were compared with the PA-DECT method.
Results:
The ML-DECT method yielded for physical density and for the six elemental mass ratios across 85 materials. Compared to the PA-DECT and SECT methods, the accuracy was improved by over 20% and 50%; the noise robustness was improved by over three times and up to 25%, respectively. In the patient dose evaluation, the ML-DECT method yielded comparable physical and biological doses, yet up to ∼1% higher LET, and up to ∼2 mm shallower peak positions than those of the PA-DECT method.
Conclusion:
The ML-DECT method provided precise estimation of physical density and elemental mass ratios of human tissues. Compared with the PA-DECT method, the ML-DECT method displayed stronger robustness to image noise.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Related Concept Videos
Chemical Ionization (CI) Mass Spectrometry
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Isotopes and Radioisotopes
An isotope containing...
Tandem Mass Spectrometry
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)