Related Experiment Video
Updated: Jan 18, 2026

Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
Comparison of supine and upright postures for liver respiratory motion management in radiotherapy
Yusuke Nomura1, Taku Inaniwa1, Yoshitake Yamada2
1Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology (QST), Chiba, Japan.
Background:
Understanding respiratory motions of liver and its surrogate organs is crucial for precise dose delivery in liver cancer radiotherapy. Although these motions have been studied for respiratory motion management in the supine posture, few studies have quantified them and evaluated their correlations in the upright posture.
Purpose:
This study quantified the respiratory motions of liver and surrogate organs and evaluated the correlations between the liver motions and surrogate signals for respiratory motion monitoring in both the supine and upright postures.
Methods:
4D dynamic volume computed tomography (CT) images were acquired from 13 asymptomatic volunteers in both supine and upright postures while free breathing. The 4D liver motions were calculated by performing deformable image registration. Subsequently, superior-inferior (SI) motion at the right diaphragm apex and anterior-posterior (AP) motion at the abdominal skin surface were obtained as surrogate signals from the 4D CT images. The average displacements and maximum magnitudes of liver motions and surrogate signals were compared between the postures. Moreover, the correlations between the liver motions and surrogate signals were evaluated based on correlation models.
Results:
The average liver displacements from the end-exhalation along the SI, AP, and left-right directions were -6.1, 2.1, and -0.4 mm in the supine posture and -4.6, 2.5, and 0.1 mm in the upright posture, respectively. The maximum motion range along the SI direction significantly decreased from 16.3 ± 6.6 mm in the supine posture to 11.0 ± 2.7 mm in the upright posture. Similar to the supine posture, the correlation models also reproduced the liver motions with high fitting accuracy in the upright posture.
Conclusions:
Compared to the conventional supine posture, the liver SI motion became smaller in the upright posture while keeping evident correlations with the surrogate signals, which suggests the upright posture will allow precise dose delivery with reduced internal target margins.
Related Concept Videos
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...

