Related Experiment Video
Updated: Jan 18, 2026

Quantification and Whole Genome Characterization of SARS-CoV-2 RNA in Wastewater and Air Samples
Published on: June 30, 2023
Risk mitigation of shared room ventilation and filtration on SARS-CoV-2 transmission: a multicenter test-negative
Victoria Williams1, Kevin L Schwartz2,3,4, Kevin Brown3,4
1Sunnybrook Health Sciences Centre, Toronto, ON, Canada.
Background:
Admission to shared hospital rooms are a risk factor of healthcare-associated (HA) SARS-CoV-2. Quantifying the impact of engineering controls such as ventilation and filtration is essential to informing resource utilization and infection prevention guidelines.
Methods:
Multicenter test-negative study of patients exposed to SARS-CoV-2 in shared rooms across five hospitals between January and October, 2022. Independent variables tested were measured air changes per hour (ACH), presence of any room mechanical ventilation (RMV), or portable high-efficiency particulate air (HEPA) filter. Covariates included facility (number of beds in room, outbreak status of unit), source patient (presence of symptoms, RT-PCR cycle threshold (Ct) value), and exposed patient factors (age, sex, time from last SARS-CoV-2 vaccine, previous SARS-CoV-2 infection, exposure duration). Multilevel logistic mixed models used to estimate the impact of engineering controls on transmission.
Results:
Among 468 exposed patients, secondary attack rate was 26.3% (range 7.5-33.3% across hospitals). In multivariable analysis, increased ACH was associated with decreased odds of infection (adjusted odds ratio (aOR) 0.88, 95% CI 0.78-1.00; p=.046) as were exposure duration and Ct value of source patient. Presence of RMV was also associated with decreased odds of infection (aOR 0.51, 95% CI 0.27-0.95; p=.034) while use of portable HEPA filter was not significant (aOR 0.58, 95% CI 0.26-1.31; p=.18).
Conclusions:
Improved ventilation was independently associated with lower odds of SARS-CoV-2 infection among exposed roommates. Ensuring RMV is present and optimizing ACH may significantly mitigate the risk of HA-SARS-CoV-2. Future prospective studies should assess optimal ACH thresholds and the impact of portable HEPA filters.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...