Related Experiment Video
Updated: Jan 18, 2026

Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
Impact of Flow Restrictors on Aerosol Delivery of the Respimat® Soft Mist Inhaler
Moritz Fleischhauer1,2, Kai Berkenfeld3, David Stadermann4,5
1Boehringer Ingelheim Pharma GmbH & Co. KG, Binger Straße 173, 55216, Ingelheim am Rhein, Germany. moritz.fleischhauer.ext@boehringer-ingelheim.com.
Introduction:
The modification of an inhaler's air flow resistance influences a patient's inhalation flow profile, thereby affecting the exit velocity of an aerosol leaving the Respimat® mouthpiece. A slower inhalation maneuver results in reduced plume velocity and thus a decreased oropharyngeal deposition due to reduced impaction. This could not only lead to fewer unwanted side effects associated with inhaled therapies, but also enhance lung deposition.
Methods:
Device prototypes with different air flow resistances were designed using custom-made inserts that can be clipped into the Respimat mouthpiece. The consequences on aerosol characteristics, as well as on in vitro deposition, were analyzed. Computational fluid dynamics simulations contributed to a better understanding of the modified aerodynamic conditions.
Results:
Different insert geometries resulted in modified device resistances. However, an increased flow resistance does not necessarily result in an improved in vitro performance. The flow restrictors critically determine aerosol characteristics such as plume velocity and spray pattern, thereby altering in vitro deposition patterns. Quantitative data on mouth-throat deposition and aerosol characteristics are reported.
Conclusions:
Integrating flow restrictors into the Respimat mouthpiece offers a promising approach to enhance patient centricity by promoting slower inhalation, thereby reducing the likelihood of suboptimal use. The use of a porous insert acting as a diffuser demonstrated minimal impact on internal airflow dynamics and in vitro deposition, suggesting that such designs can support correct inhalation technique without compromising aerosol performance. By minimizing the influence of patient-dependent factors, this strategy may help standardize the inhalation process and improve therapeutic outcomes. Video Abstract available for this article. Video Abstract (MP4 85313 KB).
More Related Videos
Related Concept Videos
Inhaled Medications
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Upper Respiratory Drugs: Antitussives, Expectorants, and Mucolytics
Antitussives include codeine, dextromethorphan (Robitussin), and benzonatate (Tessalon). Codeine and dextromethorphan exert their effects centrally by suppressing the cough reflex center in the medulla. Benzonatate operates peripherally within the respiratory tract by...
Drugs Used in Lower Respiratory Disorders: Overview
Bronchodilators, the first step of respiration enhancement, come in various forms, each with its own mechanism...