Related Experiment Video
Updated: Jan 6, 2026

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
Magnetic resonance imaging offers advantages over computer tomography for measurement of the shoulder stability ratio
Christian D Schenk1, Sebastian Oenning1, Jens Wermers2
1Department for Trauma-, Hand- and Reconstructive Surgery University Hospital Münster Münster Germany.
Purpose:
Recent studies indicate that bony shoulder stability ratio (BSSR) is a useful parameter for estimating glenohumeral stability provided by concavity-compression. In cases of bony glenoid defects, the BSSR may help to optimise surgical decision-making. However, the shapes of cartilage and labrum differ from the subchondral bony concavity. The aim of this study was to investigate the influence of cartilage and labrum on glenoid concavity and glenohumeral stability.
Methods:
Ten cadaveric shoulders were examined by computer tomography (CT) and magnetic resonance imaging (MRI). Thereby radius, depth and stability ratio in anterior-posterior and superior-inferior directions were measured. MRI measurements were performed once including and once excluding the labrum. From these, BSSR, osteochondral shoulder stability ratio (OSSR) and fibrocartilaginous shoulder stability ratio (FCSSR) were calculated, and correlations were investigated to assess the transferability between imaging modalities.
Results:
CT and MRI did not provide comparable results due to the influence of cartilage and labrum. The FCSSR showed a significantly higher stability ratio than BSSR in anterior-posterior and the same tendency in superior-inferior direction. OSSR and BSSR did not differ significantly. The labrum contributed to a significantly higher depth and lower radius in the anterior-posterior direction. Cartilage alone led to a significantly lower radius in both directions, without significant differences in depth. Comparison of CT and MRI measurements showed only weak correlations.
Conclusion:
Labrum and cartilage lead to an increased depth and decreased radius, resulting in a higher glenoid concavity and, consequently, a higher stability ratio. Comparing FCSSR and BSSR, the influence of labrum and cartilage led to a 25% higher stability ratio in anterior-posterior direction and a 7.7% higher stability ratio in superior-inferior direction. By finding no significant differences between bony and osteochondral stability ratios, the labrum of the glenoid appears to be the major factor for the increase in stability ratio. Moreover, CT and MRI measurements showed no transferability.
Level Of Evidence:
Level II, diagnostic study.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

