Related Experiment Video
Updated: Jan 18, 2026

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Phase-Contrast MRI With Hybrid One- and Two-Sided Simultaneous Three-Directional Flow-Encoding and Velocity Spectrum
Wenjian Liu1, Junpu Hu2, Jiayu Zhu2
1School of Biomedical Engineering, ShanghaiTech University, Shanghai, China.
Abstract:
A phase-contrast MRI (PC-MRI) acceleration technique was developed using hybrid one- and two-sided simultaneous three-directional flow-encoding and velocity spectrum separation (HOTSPA+). HOTSPA+ simultaneously encodes blood flow in three directions, using one-sided encoding for the z direction and two-sided encoding for both the x- and y-directions. By this encoding method, spectra of blood flow velocities in three directions can be separated from each other by temporal frequency filtering, accelerating the acquisition, and improving the flow temporal resolution. To demonstrate the benefits of HOTSPA+, common carotid data were acquired from 10 healthy volunteers and compared with the standard PC-MRI and HOTSPA, which is a previously proposed technique that can simultaneously encode flow up to two directions. Compared to the standard PC-MRI, acquisition time using HOTSPA+ was reduced by threefold, while the flow measurements showed strong correlations with R2 = 0.969 for the total volumetric flow and R2 = 0.936 for the peak velocity. The total volumetric flow showed a bias of -0.09 mL (relative bias error of 3.18%), and the peak velocity demonstrated a bias of -0.16 cm/s (relative bias error of 0.18%). When using the same acquisition time, HOTSPA+ acquired higher peak velocity and more accurate mean velocity than the standard PC-MRI, while measuring similar total volumetric flow (R2 = 0.971, bias = -0.06 mL, relative bias error = 1.19%), indicating that HOTSPA+ can also have higher flow temporal resolution than conventional methods. By simultaneously encoding the flow in three directions and using frequency filtering to separate and recover the velocities, our proposed HOTSPA+ technique can significantly reduce the scan time while accurately measuring the peak flow velocity and total volumetric flow.
Related Concept Videos
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...