Related Experiment Video
Updated: Jan 18, 2026

Building Langmuir Probes and Emissive Probes for Plasma Potential Measurements in Low Pressure, Low Temperature Plasmas
Published on: May 25, 2021
Electron density measurement in low-density plasma of electrical wire explosion using a Shack-Hartmann wavefront
Yiming Zhao1, Jian Wu1, Zhiyuan Jiang1
1National Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710049, China.
Abstract:
Measuring the electron density of low-density plasma has long been a challenge, as traditional diagnostic techniques often lack sufficient sensitivity or spatial resolution. To address this, this paper presents an electron density diagnostic method for corona plasma generated by electrical wire explosion, based on a Shack-Hartmann wavefront sensor. The diagnostic system integrates an 8 ns, 532 nm nanosecond pulsed laser, a 400 mm focal length lens array, and a high-resolution charge-coupled device camera. By integrating the proposed neural network methods with micro-lens optical simulations, we achieved sub-pixel-level centroid localization of the focal spot, reducing shift errors by 21% compared to conventional convolutional neural network methods and achieving sub-pixel accuracy with an error of only 0.25 pixels. The theoretical sensitivity of the system reaches 2 × 1015 cm-2. In experiments using a silver-wire load under pre-pulse conditions, this diagnostic technique demonstrated strong agreement with laser interferometry results in high density regions. In low-density regions, the electron density measured at 4.4 mm from the wire axis reached a minimum of 2.2 × 1016 cm-2, offering a broader spatial range for plasma electron density diagnostics compared to laser interferometry. This method effectively captured the electron density distribution of the corona plasma formed under pre-pulse conditions. Future work will focus on further optimizing the experimental system to reduce sources of error and extending the application of this technique to large-scale pulsed power facilities for diagnosing the formation and parameter distribution of low-density electrode plasmas.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Lab
Flame Photometry: Overview
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
The Hall Effect

