Towards reliable prediction of intraoperative hypotension: a cross-center evaluation of deep learning-based and
Nada Chaari1, Greg Winski2,3, Magnus Hallbäck4
1Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Hälsovägen 11, Huddinge, 141 52, Sweden. nadcha@kth.se.
Abstract:
Intraoperative hypotension (IOH) is associated with an increased risk of heart and kidney complications. Although AI tools aim to predict IOH, their real-world reliability is often overstated due to biased data selection. This study introduces a framework to enhance reliability by: (1) including borderline blood pressure cases (65-75 mmHg, the "Gray Zone"), (2) comparing AI model to simple blood pressure threshold, and (3) validating across diverse surgical cohorts, centers and demographics. Using datasets from Karolinska University Hospital (Sweden) and VitalDB (Korea), we found AI model performs better than MAP threshold method in more ambiguous cases. In contrast, when hypotensive and non-hypotensive cases had clearly separated MAP values, both methods performed similarly well. Cross-validation revealed asymmetric generalizability: models trained on datasets containing more borderline (Gray Zone) cases generalized better to datasets with clearer class separation, whereas the reverse struggled. To ensure fair model comparison and reduce dataset-specific bias, we standardized the MAP difference between positive (hypotension) and negative (non-hypotension) samples at the time of prediction. This virtually eliminated the class separation and demonstrated that inflated performance in some datasets can be attributed to selection bias rather than true model generalizability. Age also influenced generalization: Cross-age validation revealed models trained on older patients generalized better to younger cohorts, whereas differences in ASA classification had minimal effect. These findings highlight the need for realistic validation to bridge the gap between AI research and clinical practice.
More Related Videos
04:09Predicting Treatment Response to Image-Guided Therapies Using Machine Learning: An Example for Trans-Arterial Treatment of Hepatocellular Carcinoma
Published on: October 10, 2018
07:48Noninvasive and Invasive Renal Hypoxia Monitoring in a Porcine Model of Hemorrhagic Shock
Published on: October 28, 2022
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure