Related Experiment Video
Updated: Jul 9, 2026

Fundus Photography as a Convenient Tool to Study Microvascular Responses to Cardiovascular Disease Risk Factors in Epidemiological Studies
Published on: October 22, 2014
Prospective electrocardiographic and cardiovascular magnetic resonance alterations in the UK Biobank coronavirus
Sucharitha Chadalavada1, Ahmed Salih2, Hafiz Naderi1
1William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London, UK; Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, West Smithfield, London, UK.
Background:
Cardiovascular magnetic resonance (CMR) and electrocardiographic (ECG) abnormalities after coronavirus disease 2019 (COVID-19) are widely reported. However, the absence of pre-infection assessments limits causal inference from these studies. This study aims to compare interval change in CMR and ECG measures in participants with incident COVID-19 and matched uninfected controls in UK Biobank.
Methods:
UK Biobank participants with documented COVID-19 who had CMR and ECG performed before the pandemic were invited for repeat assessment, along with uninfected participants matched on age, sex, ethnicity, location, and date of baseline imaging. Automated pipelines were used to extract ECG phenotypes and CMR measures of cardiac structure and function, aortic distensibility, aortic flow, and myocardial native T1. Logistic regression was used to examine associations of baseline metrics with incident COVID-19. Standardized residual approach was used to compare the degree of interval change in CMR and ECG metrics between cases and controls.
Results:
We analyzed 2092 participants (1079 cases and 1013 controls) with average age of 60 ± 7 years. 47.1% were male. There was 3.2 ± 1.5 years between pre- and post-infection assessments. 3.6% of cases were hospitalized. Lower baseline left ventricular ejection fraction and worse longitudinal, circumferential, and radial strain were associated with higher risk of incident COVID-19. There were no significant differences in interval change of any CMR or ECG metric between cases and controls.
Conclusion:
While pre-existing cardiovascular abnormalities are linked to higher risk of COVID-19, exposure to infection does not alter interval change of highly sensitive CMR and ECG indicators of cardiovascular health.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

