Related Experiment Video
Updated: Jul 21, 2026

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
Published on: July 15, 2009
Comparative effectiveness of the socket shield technique versus conventional implantation approaches in the esthetic
Shumin Ji1, Ying Min2, Yixuan Zhang3
1Graduate student, Department of Stomatology, General Hospital of Northern Theater Command, Dalian Medical University, Dalian, PR China.
Statement Of Problem:
The socket shield technique (SST) shows promising potential in esthetic dental implantation. Nonetheless, studies on its relative efficacy in comparison with other traditional implantation methods are limited.
Purpose:
The purpose of this network meta-analysis was to comparatively evaluate SST, conventional immediate implant placement (IIP), nonimmediate implant placement with guided bone regeneration (NIIP-GBR), and nonimmediate implant placement after alveolar ridge preservation (NIIP-ARP) for optimal soft and hard tissue preservation and outcomes in the esthetic zone.
Material And Methods:
The review was registered at the International Prospective Register of Systematic Reviews (PROSPERO) (CRD42024627077) and conducted by following the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. A comprehensive systematic search was performed across the PubMed, Embase, Web of Science, Scopus, and Cochrane Library electronic databases for studies published from January 2015 to November 2024. The outcomes included pink esthetic score (PES), labial bone thickness (LBT) changes, marginal bone loss (MBL), and patient-reported esthetic outcomes (PROs). A random-effects network meta-analysis was performed, with effect sizes calculated as weighted mean differences and 95% confidence intervals. Study quality and evidence certainty were assessed using Cochrane risk of bias and Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodologies.
Results:
This network meta-analysis encompassed 19 studies, comprising 13 randomized controlled trials and 6 nonrandomized controlled trials, with a total of 760 dental implants situated in the esthetic zone. SST was associated with a superior pink esthetic score at the 6-month mark (PES-6M), showing superiority (IIP versus SST: MD=-1.31, 95%CI: -1.97, -0.66; NIIP-GBR versus SST: MD=-1.46, 95%CI: -2.80, -0.12; NIIP-ARP versus SST: MD=-1.88, 95%CI: -3.42, -0.35), and long-term follow-up over 12 months (PES-12M+, IIP versus SST: MD=-1.39, 95%CI: -1.86, -0.93; NIIP-GBR versus SST: MD=-1.50, 95%CI: -2.61, -0.40; NIIP-ARP versus SST: MD=-1.52, 95%CI: -2.97, -0.08). SST showed superiority in LBT changes (IIP versus SST: MD=0.52, 95%CI: 0.21,0.83), MBL exhibited no significant differences among comparisons. PROs indicated higher satisfaction with SST compared with IIP (MD=-0.27, 95%CI: -0.51, -0.02).
Conclusions:
Implant-supported prostheses with the socket shield technique demonstrated a superior postoperative esthetic outcome and the effective preservation of soft and hard tissues, suggesting that it is an optimal approach for the esthetic zone in patients with bone defects.
More Related Videos
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
06:36Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Masonry Curtain Walls