Related Experiment Video
Updated: Jan 18, 2026

DNA Virus Detection System Based on RPA-CRISPR/Cas12a-SPM and Deep Learning
Published on: May 10, 2024
A Simple, Rapid, and Contamination-Free Ultra-Sensitive Cronobacter sakazakii Visual Diagnostic Platform Based on RPA
Yan Liu1, Yu Xie1, Zhangli Wang1
1Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China.
Abstract:
CRISPR/Cas systems have made significant progress in the field of molecular diagnostics in recent years. To overcome the aerosol contamination problem brought on by amplicon transfer in the common two-step procedure, the "one-pot method" has become a major research hotspot in this field. However, these methods usually rely on specially designed devices or additional chemical modifications. In this study, a novel "one-pot" strategy was developed to detect the foodborne pathogen Cronobacter sakazakii (C. sakazakii). A specific sequence was screened out from the virulence gene ompA of C. sakazakii as the detection target. Combining with the recombinase polymerase amplification (RPA), a rapid detection platform for C. sakazakii based on the CRISPR/Cas12a system was established for the first time. The sensitivity of this method was determined from three different levels, which are 10-4 ng/μL for genomic DNA (gDNA), 1.43 copies/μL for target DNA, and 6 CFU/mL for pure bacterial culture. Without any microbial enrichment, the detection limits for artificially contaminated cow and goat milk powder samples were 4.65 CFU/mL and 4.35 CFU/mL, respectively. To address the problem brought on by aerosol contamination in the common RPA-CRISPR/Cas12a two-step method, a novel pipette tip-in-tube (PTIT) method for simple and sensitive one-pot nucleic acid detection was further developed under the inspiration of the capillary principle. The RPA and CRISPR/Cas systems were isolated from each other by the force balance of the solution in a pipette tip before amplification. The detection limits of the PTIT method in pure bacterial culture and the spiked samples were exactly the same as that of the two-step method, but with no false positive cases caused by aerosol contamination at all. Compared with other existing one-pot methods, the PTIT method requires no additional or specially designed devices, or any chemical modifications on crRNA and nucleic acid probes. Therefore, the PTIT method developed in this study provides a novel strategy for realizing one-pot CRISPR/Cas detection easily and holds significant potential for the rapid point-on-care testing (POCT) application.
More Related Videos
07:46On-site DNA Detection of Trypanosomatid Parasites and Nosema ceranae Through Alkaline Lysis Coupled to RPA/CRISPR/Cas12a System
Published on: July 18, 2025
07:59Rapid and Specific Detection of Acinetobacter baumannii Infections Using a Recombinase Polymerase Amplification/Cas12a-based System
Published on: April 25, 2025
Related Concept Videos
CRISPR
CRISPR and crRNAs
The CRISPR-Cas system stores a copy of foreign DNA in the host genome and uses it to identify the foreign DNA upon reinfection. CRISPR-Cas has three different...
The Antiviral System of Bacteria and Archaea: CRISPR