In order to investigate the change in the axial compression performance of circular recycled concrete-filled steel tubular short columns under chloride ion corrosion, 24 circular recycled concrete-filled steel tubular (RCFST) short columns and 12 circular natural concrete-filled steel tubular (NCFST) short columns for axial compression tests after being subjected to different corrosion degrees were designed. The experimental parameters include the corrosion degree (0, 2, 4, 6, 8, 10, 12, 14%) and the recycled concrete replacement rate (0, 100%). The experimental results show that the damage mode of the specimen after corrosion is localized buckling deformation of the steel tube. Due to the good confinement effect of the steel tube, the internal concrete was crushed only at the localized buckling part of the steel tube. The stiffness and ductility decreased significantly with increasing corrosion degree. As the corrosion degree increased from 0 to 14%, the stiffness of the circular RCFST short columns decreased by approximately 36.3%, and the ductility dropped by around 23.3%. And the corrosion resistance of the circular RCFST short column was worse than that of the circular NCFST short column. Based on the experimental results, the ultimate load capacity calculation model of the circular concrete-filled steel tubular short column is proposed.
More Related Videos
10:00Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures
Published on: August 31, 2017
06:34Finite Element Modeling for the Simulation of the Quasi-Static Compression of Corrugated Tapered Tubes
Published on: January 6, 2023
Related Concept Videos
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Design of Columns under an Eccentric Load
Effects of Creep
Reinforcements in Concrete
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...