Related Experiment Video
Updated: Apr 29, 2026

Bedside Ultrasound for Guiding Fluid Removal in Patients with Pulmonary Edema: The Reverse-FALLS Protocol
Published on: July 28, 2018
Automated Inferior Vena Cava Distensibility Index for Assessing Fluid Responsiveness in Ventilated Patients After
Amr Salah Omar1, Praveen C Sivadasan2, Suraj Sudarsanan2
1Department of Cardiothoracic Surgery/Cardiac Anesthesia & ICU Section, Heart Hospital, Hamad Medical Corporation, Doha, Qatar; Department of Critical Care Medicine, Beni Suef University, Beni Suef, Egypt; Weill Cornell Medical College-Qatar, Doha, Qatar; College of Medicine, Qatar University, Qatar.
Objectives:
This study aimed to assess the accuracy of inferior vena cava distensibility index (IVC-DI) measurements, as well as the ability to track fluid responsiveness (FR) over time.
Design:
Prospective, descriptive, single-center study.
Setting:
A single tertiary academic center.
Participants:
Fifty consecutive after cardiac surgery.
Interventions:
We compared (1) the automated echocardiographic method with (2) the stroke volume variation (SVV) technique and (3) the manual echocardiographic method.
Measurements:
FR was measured simultaneously with all 3 methods in 50 patients after cardiac surgery. A second comparison was performed 90 to 180 minutes later. The outcomes assessed included the correlations between SVV with the automated IVC-DI and the manual IVC-DI, respectively, before and after fluid challenge, as well as the accuracy of FR according to the automated and manual IVC-DI. FR is defined as an increase in cardiac output by more than 10% after receiving a fluid challenge.
Results:
A total of 50 patients who underwent cardiac surgery were included (age 51 ± 8 years; 86% males). Before the fluid challenge, a negative correlation between automated and manual IVC-DI was observed (r = -0.141; p = 0.328) with a concordance rate of 98%, although the correlation became positive after the fluid challenge (r = 0.172; p = 0.233) with a concordance rate of 98%. After fluid challenge, SVV correlation with automated IVC-DI and manual IVC-DI was positive, with the latter being statistically significant (r = 0.352; p = 0.012). FR predicted by automated IVC-DI was found to have a sensitivity of 64% and specificity 49% with a receiver operating characteristic area under the curve of 0.55.
Conclusions:
Among cardiac surgical patients, manual IVC-DI correlated significantly with SVV in assessing FR. However, the automated IVC-DI mode demonstrated less reliability.
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Pulmonary Edema II: Pathophysiology

