Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

1.4K
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.4K
Magnetic Force Between Two Parallel Currents01:13

Magnetic Force Between Two Parallel Currents

4.5K
Two long, straight, and parallel current-carrying conductors exert a force of equal magnitude on one another. The direction of the force depends on the current direction in the conductors.
The force exerted by the magnetic field due to the first conductor over a finite length of the second conductor is given as the product of the current in the second conductor and  the vector product of the length vector along the current element and the field due to the first conductor. According to the...
4.5K
Ampere-Maxwell's Law: Problem-Solving01:17

Ampere-Maxwell's Law: Problem-Solving

1.1K
A parallel-plate capacitor with capacitance C, whose plates have area A and separation distance d, is connected to a resistor R and a battery of voltage V. The current starts to flow at t = 0. What is the displacement current between the capacitor plates at time t? From the properties of the capacitor, what is the corresponding real current?
To solve the problem, we can use the equations from the analysis of an RC circuit and Maxwell's version of Ampère's law.
For the first part of the...
1.1K
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

1.6K
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
1.6K
Magnetic Field due to Moving Charges01:23

Magnetic Field due to Moving Charges

11.5K
A stationary charge creates and interacts with the electric field, while a moving charge creates a magnetic field.
Consider a point charge moving with a constant velocity. Like the electric field, the magnetic field at any point is directly proportional to the magnitude of the charge and inversely proportional to the square of the distance between the source point and the field point. However, unlike the electric field, the magnetic field is always perpendicular to the plane containing the line...
11.5K
Magnetic Field Of A Current Loop01:16

Magnetic Field Of A Current Loop

6.2K
Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
6.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Identification of the gene cluster for the dithiolopyrrolone antibiotic holomycin in Streptomyces clavuligerus.

Proceedings of the National Academy of Sciences of the United States of America·2010
Same author

Safety evaluation of tea (Camellia sinensis (L.) O. Kuntze) flower extract: assessment of mutagenicity, and acute and subchronic toxicity in rats.

Journal of ethnopharmacology·2010
Same author

Influences of soil properties and leaching on nickel toxicity to barley root elongation.

Ecotoxicology and environmental safety·2010
Same author

Effects of CO2 insufflation on cerebrum during endoscopic thyroidectomy in a porcine model.

Surgical endoscopy·2010
Same author

Plants' use of different nitrogen forms in response to crude oil contamination.

Environmental pollution (Barking, Essex : 1987)·2010
Same author

Overexpression of p35 in Min6 pancreatic beta cells induces a stressed neuron-like apoptosis.

Journal of the neurological sciences·2010

Related Experiment Video

Updated: Jan 17, 2026

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
07:01

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples

Published on: June 9, 2016

9.9K

Multipass cell SERF atomic magnetometer based on parallel plate configuration.

Yibo Qi, Shuying Wang, Zhaoyu Ye

    Optics Letters
    |September 16, 2025
    PubMed
    Summary

    We developed a new compact multipass cell for spin-exchange relaxation-free (SERF) atomic magnetometers. This design improves signal and sensitivity, enabling smaller, high-performance quantum sensors.

    More Related Videos

    Fabrication of Magnetic Platforms for Micron-Scale Organization of Interconnected Neurons
    09:54

    Fabrication of Magnetic Platforms for Micron-Scale Organization of Interconnected Neurons

    Published on: July 14, 2021

    5.2K
    Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
    07:42

    Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains

    Published on: July 20, 2022

    3.3K

    Related Experiment Videos

    Last Updated: Jan 17, 2026

    Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
    07:01

    Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples

    Published on: June 9, 2016

    9.9K
    Fabrication of Magnetic Platforms for Micron-Scale Organization of Interconnected Neurons
    09:54

    Fabrication of Magnetic Platforms for Micron-Scale Organization of Interconnected Neurons

    Published on: July 14, 2021

    5.2K
    Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
    07:42

    Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains

    Published on: July 20, 2022

    3.3K

    Area of Science:

    • Quantum Sensing
    • Atomic Physics
    • Optics

    Background:

    • Atomic magnetometers are crucial for various applications.
    • Conventional designs face limitations in size, complexity, and sensitivity.
    • Spin-exchange relaxation-free (SERF) operation offers high sensitivity but requires optimized optical configurations.

    Purpose of the Study:

    • To introduce a novel compact multipass cell for SERF atomic magnetometers.
    • To enhance signal response and sensitivity by replacing traditional reflective cavities.
    • To develop a miniaturized, high-temperature-compatible quantum sensor architecture.

    Main Methods:

    • Designed a dual-parallel plate configuration as an adjustable planar reflector.
    • Integrated a flat-top light pump to improve atomic polarization uniformity.
    • Replaced conventional reflective cavities with the new planar reflector setup.

    Main Results:

    • Achieved 1 fT/Hz½ sensitivity.
    • Demonstrated a 260% improvement in signal response.
    • Showcased a 200% increase in sensitivity compared to conventional designs.
    • The new design minimizes size and complexity while maintaining high-temperature adaptability.

    Conclusions:

    • The novel compact multipass cell design significantly advances SERF atomic magnetometer technology.
    • This architecture offers a pathway to scalable, next-generation quantum sensors with enhanced sensitivity and miniaturization.
    • The streamlined design addresses limitations of existing schemes, paving the way for practical applications.