No difference in PROMs between kinematic and mechanical alignment in TKA: An umbrella review with secondary
Johannes Stöve1, Daniel Schrednitzki2,
1Department of Orthopaedic and Trauma Surgery, Ludwigshafen, Germany.
Purpose:
To identify, synthesise and critically appraise the findings of meta-analyses that compare patient-reported outcome measures (PROMs) between unrestricted kinematic alignment and mechanical alignment in total knee arthroplasty (TKA). It was hypothesised that some meta-analyses inaccurately combine PROMs from unrestricted and restricted kinematic alignment techniques.
Methods:
Two authors independently screened articles based on inclusion and exclusion criteria and assessed the methodological quality based on the 16 domains of A MeaSurement Tool to Assess systematic Reviews (AMSTAR-2). Effect sizes of difference in PROMs were tabulated for each meta-analysis. Studies included in the meta-analyses were assessed to determine if they were on true unrestricted kinematic alignment. A secondary meta-analysis excluded studies on restricted kinematic alignment techniques, to recalculate pooled estimates (mean difference (MD) with their 95% confidence interval (CI)) of the Knee Society Score (KSS), Oxford Knee Score (OKS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Forgotten Joint Score (FJS). The quality of evidence was assessed using the GRADE.
Results:
There were 15 meta-analyses pooling data from 39 clinical studies eligible for data extraction. None fulfilled all seven critical AMSTAR-2 domains. Some reported kinematic alignment yielded superior KSS (Function, n = 9; Knee, n = 6: Combined, n = 8), OKS (n = 7), WOMAC (n = 8) and FJS (n = 1). The secondary meta-analysis included only studies on unrestricted kinematic alignment and results at the latest follow-up, for which the mean and standard deviations were reported and revealed no difference in KSS, OKS, WOMAC or FJS between kinematic and mechanical alignment. GRADE analysis revealed 'very low' quality of evidence for KSS, WOMAC and FJS, while it was 'low' quality for OKS.
Conclusion:
Current evidence suggests no difference in PROMs between kinematic and mechanical alignment in TKA. Meta-analyses that report the contrary often need more rigour as they pool studies on various kinematic alignment techniques or represent the same cohort at different times. Orthopaedic societies should promote using objective outcome measures to evaluate and compare alignment techniques.
Registration:
Systematic review protocol registration (Prospero: CRD42023434713).
Level Of Evidence:
Level III.
More Related Videos
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
07:33In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Related Concept Videos
Mechanical Efficiency of Real Machines
However, in reality, no machine can be truly ideal, and all of them experience some...
Equivalent Couples
Two couples are considered to be equivalent if they produce the same rotational effect on a rigid body. In other words, the two couples have the same magnitude and act in the same direction, causing the same angular displacement or acceleration in the body.
For instance, consider two couples lying in the plane of the page, with one having a pair of equal...
Simplification of a Force and Couple System: II
Journal Bearings
To better understand the concept of journal bearings, consider a rope winch with dry or...
Conservative Forces
Conservative forces are forces that are dependent only on the initial and final positions of an object and that are independent of the path that the object takes between these positions. These forces conserve energy, which means that the work done by the force is independent of the path...
Mechanical Systems