Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Novel multi-scan-body cone-beam CT: comparison with photon-counting and energy-integrating CT in an anthropomorphic
Falko Ensle1, Jonas Kroschke1, Elizabet Nikolova1
1Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Abstract:
BackgroundCone-beam computed tomography (CBCT) can offer advantages over multidetector CT in dose efficiency and economic costs, but musculoskeletal applications were limited in gantry-free systems.PurposeTo assess the utility of novel multi-scan-body CBCT for osseous imaging, compared to clinically implemented photon-counting-detector (PCCT) and energy-integrating-detector (EICT) CT.Material and MethodsAn anthropomorphic hand wrist phantom underwent gantry-based CBCT (low-dose, regular, enhanced, and best settings), PCCT, and EICT. Quantitative metrics included dose values, noise, and noise power spectrum (NPS). Three radiologists with varying experience levels (10, 6, and 1 years) assessed depiction of cortical and trabecular bone, articular surfaces, intraosseous ganglion cyst, and overall image quality using 5-point Likert scales.ResultsLow-dose and regular CBCT (0.37 and 0.67 mGy) showed the lowest dose values (CTDIvol), followed by EICT, enhanced and best CBCT, and then PCCT (0.76, 1.08, and 1.61, and 3.56 mGy, respectively). Absolute noise was lowest for PCCT (15.1), followed by best (23.2), regular (25.1), and enhanced (27.4) CBCT. Highest noise was measured for low-dose CBCT (35.1) and EICT (30.1). CBCT showed overall irregular and relatively high NPS, compared to regular and high NPS of EID, whereas PCCT showed a cleaner texture with the lowest NPS. Qualitatively, CBCT (enhanced, best) generally achieved the best scores, while the other scans scored equally well. Average interreader agreement ranged from moderate to near-perfect (k = 0.53-0.87).ConclusionNovel multi-scan-body CBCT with variable image quality settings can provide detailed depiction of fine osseous structures, demonstrating comparable or lower doses compared to clinically implemented PCCT and EICT.
More Related Videos
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
07:33Non-invasive Skeletal Muscle Quantification in Small Animals Using Micro-computed Tomography
Published on: November 8, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET