Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Integrating a Multimodal Digital Device for Continuous Perioperative Monitoring in Patients With Lung Cancer
Runchen Wang1, Jianqi Zheng1, Wenwei Guo1
1Department of Thoracic Surgery, China State Key Laboratory of Respiratory Disease & National Clinical Research Center for Respiratory Disease, the First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
Background:
Minimally invasive thoracic surgery has improved lung cancer outcomes but requires enhanced postoperative care. Traditionally, the episodic care model has limited timely and multidimensional monitoring of patients. Recent technological advances in multimodal digital devices, including wearable devices and electronic patient-reported outcomes (ePROs), offer a promising solution to these challenges. However, current studies focus on only a few parameters and limited application in thoracic surgery.
Objective:
This study aims to propose a self-controlled study to evaluate the feasibility and reliability of multimodal digital devices, including wearables and ePROs, for continuous perioperative monitoring to enhance recovery after thoracic surgery.
Methods:
We included 288 patients with non-small cell lung cancer from the Guangzhou Medical University cohort, which includes 2757 participants with various lung diseases. Digital data were collected during hospitalization using a commercial smartwatch combined with an ePROs questionnaire, while clinical data were obtained from electronic health records (EHRs). Agreement between the digital device and EHR was evaluated via Bland-Altman analysis. Time-series data were normalized for continuous outlier monitoring, and threshold analysis of ePROs scores were used to explore associations across different modules.
Results:
Throughout hospitalization, digital devices provided a subjective overview of the patients' recovery trajectories. Results of Bland-Altman analysis demonstrated a high level of agreement between the digital device and the EHR. For body temperature, the analysis revealed a minimal bias of 0.02 °C (95% CI -0.01 °C to 0.05 °C), the agreement for heart rate showed a bias of 0.26 beats per minute (bpm; 95% CI -0.49 bpm to 1.01 bpm), and the bias for oxygen saturation was -0.06% (95% CI -0.27% to 0.15%), indicating close alignment between the 2 measurement methods. Meanwhile, wearable devices demonstrate significant potential in outlier detection compared to the episodic care model, offering accurate and sensitive monitoring of outliers between traditional measurement intervals. Using a thresholding method, we found that wearable metrics were correlated with the severity of ePROs.
Conclusions:
These findings highlight the reliability and clinical potential of digital device-based multimodal systems within the enhanced recovery after surgery framework, offering a novel approach for continuous perioperative monitoring.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...