Related Experiment Video
Updated: May 8, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Impact of physiological and biomechanical parameters on lung deformation and the accuracy of lung tumor motion
Hamid Ladjal1, Behzad Shariat1
1Université Claude Bernard Lyon 1, LIRIS CNRS - UMR 5205, 23-25 Av. Pierre de Coubertin, 69100, Villeurbanne, France.
Abstract:
Patient-specific biomechanical models of the respiratory system can enhance the prediction of lung tumor positions and deformations for radiation therapy. To achieve this, we have developed a patient-specific biomechanical model of the entire respiratory system. However, the accuracy of the simulation is highly influenced by mechanical behavior as well as biomechanical and physiological properties. In this study, we have investigated the impact of simplification and variability in mechanical and physiological property uncertainties on lung tumor motion prediction. Specifically, we have evaluated and compared the most commonly used values of the lung tissue Young's modulus and Poisson's ratio found in the literature. Furthermore, we have examined the effect of a simple and fast linear compliance model versus a nonlinear, personalized physiological lung compliance model in computing lung and diaphragm strain. We have also explored the impact of different nonlinear behavior models to identify the most suitable mechanical model for respiratory simulation. To this end, we have conducted a study on four widely referenced hyperelastic models. Numerical simulations were performed on public datasets using the Neo-Hooke, Yeoh, Mooney-Rivlin, and St. Venant-Kirchhoff hyperelastic models. We have observed that nonlinear personalized compliance enhances accuracy and yields better results compared to linear compliance. The simulations in this study showed minimal and negligible variations with different values of Young's modulus. In contrast, variations in Poisson's ratio significantly impacted the simulation results. In our simulations, the Saint-Venant-Kirchhoff and Mooney-Rivlin models demonstrated the highest accuracy for simulating lung tissue across all phases of respiration, with an average landmark error of 2.1±1.3mm. This model has the potential to provide precise tumor motion predictions, helping physicians reduce safety margins and minimize damage to healthy tissues during radiation therapy.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...

