Related Experiment Video
Updated: Jun 14, 2026

Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves
Published on: October 17, 2013
Reducing blood component wastage through targeted interventions: A four-year retrospective study at a Saudi tertiary
Wajnat A Tounsi1, Osama A Alzahrani2, Ahmed Q Bukhari1
1Department of Medical Laboratory Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia.
Background:
Blood transfusion services are vital to healthcare; however, blood component wastage remains a persistent challenge for transfusion facilities, impacting resource efficiency and patient care. In this four-year retrospective before-and-after study, we investigated blood component wastage at a tertiary hospital in Saudi Arabia to identify key causes of wastage and evaluate the impact of targeted interventions introduced in 2024.
Methods:
Statistical analyses included z-tests for rate comparisons, effect size estimation using Cohen's h, and 95% confidence intervals (CIs) to assess the impact of the interventions.
Results:
From 2021 to 2024, 83,185 components were prepared and 13,954 units were discarded. Between 2021 and 2023, the average waste rate was 19.44%. Leading causes included expiration (28.40%), TTI screening reactivity (20.11%), and low platelet yield (18.39%). Following the 2024 implementation of targeted measures-including improved inventory policies, donor screening, and transfusion practices-total waste declined by 35.71% (p < 0.001, 95% CI: 0.016 to 0.024), with a moderate effect size (Cohen's h = 0.20). Total monthly waste rates were also significantly reduced (mean difference of 7.73 percentage points; p < 0.001, 95% CI: 4.87% to 10.59%, Cohen's d = 2.29). The WAPI scores improved across all components, and associated costs were reduced by 15.9%, saving approximately SAR 171366 (US$45856).
Conclusion: