Introduction And Aims:
This study evaluated heat transfer to the periodontal ligament (PDL) of simulated teeth with internal root resorption (IRR) cavities of varying diameters during thermoplasticized obturation.
Methods:
Three-dimensional finite-element tooth models with IRR cavities of diameters 3, 3.5, 4, and 4.5 mm were constructed based on microcomputed scanning tomography of a maxillary central incisor tooth. Four digital models (V/3, V/3.5/, V/4, and V/4.5) were reconstructed with vascularized PDL layer and bone, and one without PDL vascularity (nonvascular/4.5) was also created to evaluate the effect of blood flow. Root canals were obturated using a simulated continuous wave of compaction technique. Additional simulations were conducted to evaluate the Effects of incorrect heat-carrier angulation at (200°C and 300°C) and backpacking with reduced gutta-percha temperature (100°C) on PDL heat transfer in the largest resorptive model were also simulated. Heat transfer to PDL was calculated to determine whether it exceeded the critical temperature.
Results:
PDL temperatures remained below 47°C threshold during the downpack across all resorption models. In the backfill phase, PDL temperature in models with 4 and 4.5 mm diameter IRR cavities exceeded the critical level with thermoplasticized gutta-percha at 200°C. The vascularized model consistently registered lower PDL temperature than its nonvascularized counterpart.
Conclusions:
Based on our findings, backfilling gutta-percha heated to 200°C in large IRR cavities may cause high temperature rise in the PDL. Therefore, when treating IRR cases, the size of the resorptive cavity should be considered, and treatment strategies that minimize heat generation are preferred.
Clinical Relevance:
Large IRR cavities can lead to harmful heat transfer to the PDL during heat-dependent obturation techniques. Clinicians should consider cavity size and use proper heat-minimizing measures to prevent PDL damage, especially during backfilling with high-temperature gutta-percha.
More Related Videos
Related Concept Videos
Mechanism of heat transfer
Mechanisms of Heat Transfer I
Mechanisms of Heat Transfer II
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55 °C.
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
Mechanisms of Heat Transfer
Conduction, accounting for approximately 3% of body heat loss at rest, is the process of exchanging heat between molecules of two materials in direct contact. This can result in both heat loss and gain. For instance, when the body is submerged in water, which conducts heat 20 times more effectively than air, it can either lose or gain significant heat.