Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis
Published on: December 16, 2016
Inter-instrument definition of valid criteria for the automatic identification of microplastics by micro-Raman
Rafaela Fernandes1, Paul-Tiberiu Miclea2, Marta Fadda3
1Centro de Química Estrutural, Institute of Molecular Sciences, Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa, Portugal.
Abstract:
The assessment of the impact of microplastic contamination on the environment and human health requires a reliable identification of the polymer type of these particles. μ-Raman spectroscopy is a popular technique for identifying microplastics by comparing the reference spectra with those of the particles analysed. Automatic identification of microplastics requires defining an algorithm for the match between these spectra and setting a minimum match above which identification is performed with adequately high true and low false results rates. Ideally, the algorithm and match threshold should apply to different spectrometers and spectra collection parameters. This research presents a methodology to determine the best match algorithm for polymer identification using μ-Raman spectroscopy data collected on different instruments and laboratories, associated with a true positive rate (TP) of 95 % and a false positive rate (FP) lower than 5 %. Determining the match threshold (P5»P) by the bootstrap method does not require assumptions regarding match distribution. The normal distribution of the match between the reference and a particle's spectra from a different material allows FP determination. Identifying PET microparticles was optimal using Pearson's correlation coefficient (P5»P = 0.6244, TP = 95 %, FP = 4.9 × 10-7 %). Identification quality was tested based on three unweighted and three weighted correlation coefficients. Spectra with signal-to-noise ratios lower than 10 were forwarded to manual identifications. The MS Excel files used in the research are available as supporting information. The developed methodology for setting up identification criteria of microplastics by spectroscopy proved to be adequate for μ-Raman assessments and robust to different spectrometers and spectra collection conditions.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...