Electrochemically and Bioelectrochemically Induced Ammonium Recovery
Published on: January 22, 2015
Concentrating Ammonia from Wastewater with Electrodialysis
Hyuck Joo Choi1, Mohammed Tahmid1, Spandan Mondal1
1School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, 311 Ferst Drive NW, Atlanta, Georgia 30332, United States.
None:
Electrodialysis (ED) is a promising technology for the recovery of ammonia from wastewater. However, separating ammonia directly from complex wastewater mixtures using ED is challenging due to membrane scaling, low selectivity, and high energy consumption. Here, we evaluate the potential of electrodialysis for ammonia recovery from simulated and real wastewater mixtures. The specific energy consumption (SEC) of electrodialysis exceeded 31 kWh/kg-N for simulated wastewater but decreased 4-fold to 7 kWh/kg-N after hardness removal. Concentration factors (CFs), the final concentration relative to the initial concentration, of NH4 + for real wastewater after ultrafiltration and for synthetic wastewater without hardness were 7.5 and 10, comparable to the CF of 9 for single-salt solutions (nonmixtures). We find that the concentrated product after ED with real and simulated synthetic wastewater includes K+ and Na+, as cation exchange membranes exhibit K+/NH4 + and Na+/NH4 + selectivities near one. Thus, if the concentrated product is directly used as an aqueous fertilizer, the resulting product will be 30/30/30 for Na+, K+, and NH4 +. Finally, staged electrodialysis achieved a CF of ∼50 (2.42 N wt %) with SECs of 15.2-18.1 kWh/kg-N for synthetic wastewater without hardness, demonstrating promise for recovering ammonia from wastewater with a high concentration and low energy demand.
Related Concept Videos
Dialysis
Preparation of Amines: Alkylation of Ammonia and Amines
Each alkylation step makes the nitrogen center more nucleophilic, which triggers successive alkylations until a quaternary ammonium salt is formed. Considering...
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Comparative Excretory Systems
Physiology of the Genitourinary System III: Urine Concentration and Dilution
Common Ion Effect