Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Suprasternal ascending or descending aortic velocity peak variability assessment to predict fluid-responsiveness in
Filippo Sanfilippo1,2, Cristina Santonocito3, Mateusz Zawadka4
1Department of Anaesthesia and Intensive Care, A.O.U. Policlinico-San Marco, Site "Policlinico G. Rodolico", Via S. Sofia N 78, 95123, Catania, Italy. filipposanfi@yahoo.it.
Aim:
Evaluating fluid responsiveness (FR) is crucial in managing critically ill patients. Measurement of respiratory variations of blood flow (Vpeak) is physiologically sound, but blood flow sampling through the aortic valve (AV-Vpeak) is not always feasible. We assessed the feasibility of suprasternal Vpeak (SS-Vpeak), at ascending or descending aorta level, as alternative to AV-Vpeak.
Methods:
Observational prospective study in spontaneously breathing healthy volunteers. We report the overall feasibility of AV- and SS-Vpeak, and calculated their interchangeability, the mean bias with limits of agreement (LoA) and percentage error (PE). We defined FR as a 10% increase in cardiac output measured non-invasively with finger-cuff method after passive leg raising.
Results:
We enrolled 67 volunteers; SS-Vpeak was feasible in 65 volunteers (97%), with sampling in the ascending and descending aorta in 22/65 (33.8%) and 43/65 (66.2%) volunteers, respectively. AV-Vpeak was feasible in 64 volunteers (95.5%). When both Vpeak were obtained (n = 62), interchangeability using a 12% cut-off was 67.7% (poor agreement with kappa coefficient 0.19 [-0.02;0.41]). Clinical concordance at ascending aorta level was non-significantly higher (16/22, 73% vs 26/40, 65%; p = 0.583). Prediction of FR with SS-Vpeak using the 12% cut-off was poor: sensitivity 85%; specificity 9%; positive predictive value 82%; negative predictive value 11%. Bland-Altman's analysis revealed a mean bias -2.6% [-4.3%;-1.0%] with LoA ranging from -15.2% [- 18.1%;- 12.4%] to 10.0% [7.2%;12.8%]. The mean PE was 7.87%.
Conclusions:
We report excellent feasibility for SS-Vpeak, though with moderate interchangeability and accuracy; however, we found poor precision and poor performances in predicting FR in healthy volunteers.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)