Quantification of 18F-FDG Delivery Rate for Liver Inflammation Using Shortened Dynamic PET Imaging Protocols
Xiaoyu Duan1, Souvik Sarkar1,2, Victoria Lyo3
1Department of Radiology, University of California Davis Health, Sacramento, California.
None:
Liver inflammation is a diagnostic hallmark of metabolic dysfunction-associated steatohepatitis (MASH), a severe form of chronic metabolic dysfunction-associated steatotic liver disease. 18F-FDG delivery rate (K 1) in the liver, measured by dynamic PET with tracer kinetic modeling, has the potential to assess liver inflammation and diagnose MASH noninvasively. However, a 1-h scan protocol is typically used to generate the liver [Formula: see text], which is less practical for clinical use. In this study, we aimed to investigate shortened scan protocols for quantification of liver 18F-FDG [Formula: see text] in patients with MASH. Methods: Eighty-two subjects, including 68 patients with metabolic dysfunction-associated steatotic liver disease and 14 healthy volunteers, were scanned on either a short-axial-field-of-view PET/CT scanner or a total-body PET/CT system following a full 1-h dynamic scan protocol. Two shortened scan protocols were proposed with appropriate tracer kinetic models: a 15-min dynamic scan with a 2-tissue reversible model and a 10-min dynamic scan with a 2-tissue irreversible model. Liver [Formula: see text] values generated from the shortened scan protocols were compared with those generated from the full 1-h scan and used to assess biopsy-determined liver inflammation and MASH using receiver-operating-characteristic analysis. Results: Liver 18F-FDG [Formula: see text] values generated from the shortened scan protocols were approximately equal to [Formula: see text] values generated from the full 1-h scan. Such [Formula: see text] showed equivalent capability to differentiate between healthy, low-inflammation, and high-inflammation groups (P < 0.0005), similar to the [Formula: see text] obtained from a full 1-h scan. When combined with liver CT that assesses steatosis, the 2 shortened scan protocols achieved an area under the curve of 0.95 for receiver-operating-characteristic analysis when differentiating MASH and non-MASH with both scanners. Conclusion: It is feasible to develop a liver PET/CT parametric imaging approach using a dynamic scan of 15 min or less with an appropriate tracer kinetic model for evaluating liver inflammation and diagnosing MASH on both total-body and conventional PET scanners. The 2 proposed shortened scan protocols are more practical than the 1-h protocol for measuring liver 18F-FDG [Formula: see text].
More Related Videos
10:04Radionuclide-fluorescence Reporter Gene Imaging to Track Tumor Progression in Rodent Tumor Models
Published on: March 13, 2018
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)