This paper discusses the issue of the self-heating effect of resistance sensors during temperature measurement. The self-heating effect causes temperature measurement errors. The aim of this work was to develop a method for in situ assessment of the thermal resistance between a self-heating thermometer and its surrounding environment, the temperature of which is measured. The proposed method is used to assess the uncertainty resulting from the heat transfer from the thermometer to the surrounding environment, which allows increased measurement accuracy. The proposed method consists of experimental determination of the sensor's temperature characteristics in relation to the heating power for different values of the measuring current. Sample measurements were carried out on a representative group of resistance temperature sensors. The relationship of the internal thermal resistance to the type of sensor design and the relationship of the external resistance to the ambient conditions were demonstrated. The developed method allows the appropriate measuring current of the resistance temperature sensor to be selected according to its design, the mounting method, and the environmental conditions, which ensures that measurement errors are maintained at an appropriately low level.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Resistance
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...