High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Method development for the analysis of synthesis markers from clandestine amphetamine production via the Leuckart
Maximilian Greif1, Jennifer Rosin2, Thorsten Rößler3
1Federal Criminal Police Office, Forensic Science Institute, Äppelallee 45, Wiesbaden 65203, Germany; Hochschule Fresenius, Institute for Analytical Research, Limburger Straße 2, Idstein 65510, Germany.
Abstract:
Clandestine amphetamine synthesis via the Leuckart route generates large amounts of toxic aqueous production waste, often disposed into the sewer system by criminal producers. The detection of synthesis markers from production waste by wastewater analysis can indicate waste disposal and contribute to the localization of a clandestine laboratory responsible for the discharge. Traditional approaches usually require laborious sample acquisition and preparation. In this study, polydimethylsiloxane (PDMS) rods were investigated for their use as passive samplers, which enable isolation and enrichment from complex aqueous matrices in a single step, followed by direct analysis by thermal desorption gas chromatography - mass spectrometry (TD-GC-MS) techniques. In this work, the suitability of PDMS rods for extraction of amphetamine synthesis markers from the Leuckart route in wastewater influent is systematically tested and evaluated. The extraction procedure was optimized for five target compounds, yielding extraction efficiencies from 9 % to 82 %. Furthermore, two TD-GC-MS methods using a bench-top and a portable instrument for potential rapid on-site analysis were validated. The overall methodology proved to be repeatable with RSDs from 4.4 % to 20.1 % (bench-top system) and from 6.6 % to 14.8 % (portable system). Lowest LOD values for a single compound (4-methyl-5-phenylpyrimidine) were 0.9 and 1.5 ng in 10 mL samples for the bench-top and portable system, respectively. Analysis of wastewater samples spiked with real production waste highlighted the wide range of compounds that can be extracted using PDMS rods. Furthermore, the application of PDMS rods in forensic case work is described.
More Related Videos
13:16A Whole Cell Bioreporter Approach to Assess Transport and Bioavailability of Organic Contaminants in Water Unsaturated Systems
Published on: December 24, 2014
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019