Two-Year Visual, Refractive, and Anatomical Outcomes of Sutureless, Intrascleral, 1-Piece Intraocular Lens Fixation:
Paola Marolo1, Guglielmo Parisi1, Fabio Conte1
1Department of Surgical Sciences, Section of Ophthalmology, University of Turin, Turin, Italy.
Purpose:
To evaluate the 2-year visual, refractive, and anatomical outcomes of a foldable single-piece intraocular lens (IOL) specifically designed for sutureless intrascleral fixation in eyes without adequate capsular support.
Design:
Prospective, observational, multicenter study.
Participants:
Two hundred thirty-four eyes of 232 patients undergoing secondary IOL implantation using a standardized sutureless intrascleral fixation technique.
Methods:
All eyes received a foldable, 1-piece acrylic IOL implanted via a scleral flap technique. Best-corrected visual acuity (BCVA), spherical equivalent (SE), refractive prediction error (PE), and endothelial cell density (ECD) were assessed at baseline, 12 months, and 24 months. A subgroup analysis using anterior segment OCT evaluated IOL tilt, decentration, and surgically induced astigmatism (SIA), Multivariate regression explored biometric predictors of refractive outcomes.
Main Outcome Measures:
Changes in BCVA, refractive stability, PE, IOL tilt and decentration, ECD, and postoperative complications.
Results:
Mean BCVA improved from 0.74 ± 0.30 to 0.26 ± 0.24 logMAR at 24 months (P < 0.001). Spherical equivalent changed from 3.52 ± 5.92 diopters (D) at baseline to -0.33 ± 0.85 D at 24 months (P < 0.001). A PE within ±1.00 D was achieved in 77% of eyes. Mean absolute SIA remained stable (0.86 ± 0.44 D at 12 months vs. 0.90 ± 0.62 D at 24 months; P = 0.911). Intraocular lens tilt and decentration showed no significant change over time. ECD was preserved (P = 0.895). Visual decline occurred in 2.56% of eyes and no cases of IOL dislocation or endophthalmitis were observed.
Conclusions:
Sutureless intrascleral fixation of a single-piece foldable IOL may lead to sustained visual improvement, high refractive accuracy, stable anatomical positioning, and a low rate of complications over 24 months. This technique demonstrates good tolerability and is associated with favorable visual outcomes for secondary implantation in eyes lacking capsular support.
Financial Disclosure(S):
Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
More Related Videos
05:56Scleral Cross-linking Using Riboflavin and Ultraviolet-A Radiation for Prevention of Axial Myopia in a Rabbit Model
Published on: April 3, 2016
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment