Defining "Paradoxical Instability" and Other Indications for Aseptic Single-Component Polyethylene Revision: A Cohort
Robert Schmidt1,2, Winston Scambler1,2, Jack A Will1,2
1Department of Research, Texas Hip and Knee Foundation, Fort Worth, TX, USA.
Background:
Single-component polyethylene revision (SCPR) is a less invasive approach for addressing polyethylene wear in total knee arthroplasty by replacing only the tibial polyethylene component. While traditionally used for aseptic ligamentous mid-flexion instability and limited arc of motion, this study introduces paradoxical instability as a third indication, characterized by ligamentous laxity with knee effusion causing mid-flexion instability and secondary flexion contracture.
Methods:
A retrospective study analyzed 58 consecutive SCPR patients treated by a single fellowship-trained surgeon between 2012 and 2024, with a minimum 2-year follow-up. The cohort included 20 men (34%) and 38 women (66%), with a mean age of 70.2 years and average follow-up of 2.83 years. Patients were categorized into 3 groups: mid-flexion instability (n = 43), limited arc of motion (n = 9), and paradoxical instability (n = 6). Outcomes were assessed using clinical examinations and Knee Society Score 2011 and UCLA activity scores.
Results:
Clinical success rates defined as good to excellent clinical outcomes were 88.3% (38 of 43) for mid-flexion instability, 88.8% (8 of 9) for limited arc of motion, and 100% (6 of 6) for paradoxical instability patients. No readmissions or reoperations occurred within 90 days postsurgery. The mean hospital stay was 0.87 days.
Conclusions:
SCPR demonstrated effectiveness in treating all 3 indications, with particularly promising results for paradoxical instability cases. This study establishes paradoxical instability as a distinct clinical entity characterized by knee imbalance, mid-flexion instability, recurrent effusions, and limited motion arc. This limited motion arc is paradoxically treated with an increase of polyethylene thickness. The findings support SCPR as a viable treatment option for carefully selected patients with these conditions.
More Related Videos
Related Concept Videos
Stability of Substituted Cyclohexanes
The two chair conformations of cyclohexanes undergo rapid interconversion at room temperature. Both forms have identical energies and stabilities, each comprising equal amounts of the equilibrium mixture. Replacing a hydrogen atom with a functional group makes the two conformations energetically non-equivalent.
For example, in...
Microtubule Instability
Microtubule Instability
Stability of Conjugated Dienes
A comparison of the enthalpies of hydrogenation of dienes reveals that conjugated dienes release less heat on hydrogenation, rendering them more stable than their nonconjugated analogs.
Polymers: Molecular Weight Distribution
Molecular Weight of Step-Growth Polymers
As the step-growth polymerization involves step-wise condensation of monomers, the molecular weight also builds up eventually. Consequently, high molecular weight polymers are obtained at the late stages of the polymerization, where 99% of monomers have been consumed.
The extent of the...