Investigating the fire dynamics of mounted PV weathering effects and material changes

Muhsin Mohamed Baseer Ahamed Mohamed1, Ye Xian Ang1, Rhonda Jia Hui Tan1

  • 1School of Materials Science and Engineering, Nanyang Technological University, Singapore, Singapore.

Iscience
|September 22, 2025
PubMed
Abstract

Related Concept Videos

Masonry in Cold and Hot Weather Conditions01:21

Masonry in Cold and Hot Weather Conditions

In cold weather, masonry construction requires specific precautions to ensure mortar does not freeze before curing, as this can significantly weaken its strength and watertightness. Mortar temperature should be maintained between 60°F and 80°F to support proper hydration and curing. Below 40°F, mortar water must be heated, but should not exceed 120°F as high temperatures can reduce mortar's compressive and bond strength.
Other key practices include keeping masonry units...
332
Frost Action on Concrete01:27

Frost Action on Concrete

Concrete structures in cold climates, such as those along roadsides, can retain moisture. This moisture makes them susceptible to frost-related damage when temperatures fall below freezing. Adding moisture worsens the damage during temperature fluctuations, leading to repeated freezing and thawing. De-icing salts, spread over these structures to melt ice, add to the freeze-thaw cycle, and draw even more moisture into the concrete.
This freeze-thaw cycle primarily causes surface scaling, where...
400
Design Example: Calculating Safe Diameter for Wind-Exposed Disc01:17

Design Example: Calculating Safe Diameter for Wind-Exposed Disc

Assessing safety in wind-exposed installations is crucial to preventing potential failures. This example explores the calculation and design adjustments needed to mount a circular disc on a building facade, where wind forces are a primary concern. A 4-meter diameter disc was initially designed as an aesthetic feature facing winds at a velocity of 25 meters per second, with an air density of 1.25 kilograms per cubic meter. Given these conditions, the drag force on the disc was determined using...
355
Turbine-Governor Control01:17

Turbine-Governor Control

Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
933
Faraday Disk Dynamo01:23

Faraday Disk Dynamo

A Faraday disk dynamo is a DC generator, producing an emf that is constant in time. It consists of a conducting disk that rotates with a constant angular velocity in the magnetic field, perpendicular to the disk's plane. The rotation of the disk causes a change in magnetic flux, which induces an emf, causing opposite charges to develop on the rim and in the center of the disk. The polarity of the induced emf can be determined by the direction of the magnetic field and the direction of the...
3.5K
What is Weather?01:07

What is Weather?

Overview
19.8K