Related Experiment Video
Updated: Jan 17, 2026

Designing CAD/CAM Surgical Guides for Maxillary Reconstruction Using an In-house Approach
Published on: August 24, 2018
Impact of CAD-CAM technology and abutment angulation on prosthesis design for anterior maxillary implants: An
V Santoshi Kumari1, Kasi Reddy Snehalatha Reddy2, Anusha Borra1
1Department of Prosthodontics, Malla Reddy institute of dental Sciences, Malla Reddy Vishwavidyapeeth, Hyderabad, India.
Abstract:
The clinical performance of anterior maxillary implants restored using CAD-CAM technology, emphasizing the influence of abutment angulation, restorative material and occlusal scheme on treatment outcomes is of interest. Among 49 patients assessed, implants with 0° abutments exhibited superior prosthetic success, marked by minimal complications and enhanced retention. Layered zirconia restorations delivered the most favorable esthetic results, while canine-guided occlusion correlated with heightened patient satisfaction. Thus, the pivotal role of precise angulation, material selection and occlusal dynamics in optimizing the functional and aesthetic success of anterior implant restorations is shown.