Related Experiment Video
Updated: Jul 21, 2026

Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Characterizing deterioration of milk through bioimpedance spectroscopy
Abhishek Mallick1, Bishal Paul1, Anirudhha Roy2,3
1Department of Electronics, West Bengal State University, Kolkata, Barasat 700126, India.
This study uses electronic sensors to measure milk bioimpedance, finding that relaxation-time decreases with adulteration. This method effectively detects milk spoilage within hours, advising against consumption after two hours at room temperature.
Area of Science:
- Food science and technology
- Electrical engineering
- Biomedical engineering
Background:
- Liquid milk quality assessment is crucial for consumer safety and industry standards.
- Electronic sensors offer a non-destructive method for real-time milk analysis.
- Bioimpedance spectroscopy is a promising technique for characterizing biological materials.
Purpose of the Study:
- To develop and validate an electronic sensor-based method for milk quality assessment.
- To characterize milk adulteration using bioimpedance spectroscopy.
- To establish a correlation between bioimpedance parameters and milk spoilage.
Main Methods:
- Fabrication of a cylinder-in-cylinder sample holder for bioimpedance measurements.
- Conducting bioimpedance spectroscopy on raw and pasteurized milk during adulteration at 23°C.
- Modeling milk bioimpedance using the Cole equivalent circuit and extracting parameters.
- Estimating relaxation-time from Cole parameters and performing statistical analysis.
Main Results:
- The developed method successfully discriminated between different brands of liquid milk.
- Relaxation-time showed a monotonic decrease with increasing adulteration time for all milk types.
- Adulteration effects were significant within the first three hours at 23°C.
- A clear correlation was established between relaxation-time and the extent of milk adulteration.
Conclusions:
- Electronic sensor-based bioimpedance spectroscopy is effective for real-time milk quality assessment and adulteration detection.
- Relaxation-time serves as a reliable indicator of milk spoilage.
- Consumption of milk adulterated and kept at 23°C is not advisable after two hours due to significant quality degradation.