Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Remote sensing of flammable and toxic gases via IPDA lidar with InGaAs/InP single-photon detector over C + L band
Abstract:
An integrated path differential absorption lidar (IPDA) for remote sensing of flammable and toxic gases is proposed, which is based on a broadband-tunable external-cavity diode laser (ECDL) and InGaAs/InP single-photon detector (SPD). An ECDL can maintain a narrow linewidth of 10 kHz throughout the continuous frequency scanning process in the C + L-band (1520-1620 nm), thus allowing a single laser to satisfy the detection requirements of multiple gases. To eliminate the influence of background light, a programmable frequency- and bandwidth-tunable grating filter is designed to synchronously tune with the output frequency of the ECDL. A homemade multi-channel coupled InGaAs/InP SPD maintains high detection efficiency in the C + L-band, ensuring the remote sensing detection capability of lidar. Four gases-CO, H13CN, C2H2, and NH3-with absorption lines spanning ∼45 nm in wavelength are selected to verify the multi-gas monitoring capability of the lidar. The intensity errors caused by erroneous photon counts and the non-linear frequency caused by the hysteresis effect of piezoelectric ceramic transducer are corrected to enhance the accuracy of absorbance spectra. The standard deviations of residuals between the experiment and single-peak fitting results for CO, H13CN, C2H2 are 0.22%, 0.54%, 0.39%, while the mean deviations are 0.19%, 0.44%, 0.29%, respectively. For the four-peak fitting of NH3, those values are 0.55% and 0.38%, respectively. Continuous 12-hour monitoring of the path-integrated concentrations of the four gases is conducted to verify the stability and accuracy of the system. The mean deviations and standard deviations of CO, H13CN, C2H2, and NH3 are 0.13%, 0.13%, 0.02%, 0.17%, and 1.07%, 1.68%, 1.21%, 0.67%, respectively.
More Related Videos
12:57Resonance Fluorescence of an InGaAs Quantum Dot in a Planar Cavity Using Orthogonal Excitation and Detection
Published on: October 13, 2017
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Flame Photometry: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation