Energy concentration-based optimization of Gaussian window reassignment for time-frequency analysis, and its
Henok Mezemr Besfat1, Demissie Jobir Gelmecha2, Ram Sewak Singh3
1Department of Electrical and Computer Engineering, Woldia University, Woldia, 400, Ethiopia.
Abstract:
The non-stationary nature of cardiovascular signals necessitates time-frequency (TF) methodologies that can precisely capture and characterize temporal variations in their frequency components. This study aims to explore the Non-Stationary Spectral Coherence (NSSC) characteristics between cardiovascular signals, including heart rate variability (HRV), respiratory (RESP), systolic arterial blood pressure variability (SABPV), and arterial pressure interval variability (APIV), of healthy young (yng) and elderly (eldy) subjects to understand cardiovascular control. For this analysis, an optimized Gaussian window reassignment (OptGWRS) TF technique is proposed to capture the characteristics of these signals. The parameters of the Gaussian window are optimized using a particle swarm optimization (PSO) algorithm to maximize the energy concentration of signals in the TF domain. Initially, the proposed method was validated using synthetic stationary and non-stationary time series data that flow the dynamic characteristics of cardiovascular signals within the low-frequency 0.04 to 0.15 Hz (LF) and high-frequency 0.15 to 0.4 Hz. (HF) band. The simulation results have demonstrated that the proposed method provided a more energy concentration and achieved a higher TF resolution. Furthermore, this method was applied to a real database. The simulation results have shown that the NSSC ranges between the HRV and APIV signals in the low frequency band has been significantly reduced (p = 0.000001) in the eldy group when compared to the yng group. In the LF band, the NSSC among HRV and RESP signals have not been influenced by aging and, in the HF band significantly reduced in the eldy compared to the yng group (p = 0.0125).
More Related Videos
Related Concept Videos
Effective Value of a Periodic Waveform
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Energy and Power Signals
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
Continuous -time Fourier Transform