Related Experiment Video
Updated: Jan 17, 2026

Qualitative Identification of Carboxylic Acids, Boronic Acids, and Amines Using Cruciform Fluorophores
Published on: August 19, 2013
Development of a green spectrofluorimetric method for mefenamic acid determination using Rhodamine 6G with
Arwa Sultan Alqahtani1, Maram H Abduljabbar2, Reem M Alnemari3
1Department of Chemistry, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU) P.O. Box 90950 Riyadh 11623 Saudi Arabia.
Abstract:
Spectrofluorimetry has emerged as a powerful analytical technique offering high sensitivity, selectivity, and environmental compatibility for pharmaceutical analysis. This study aims to develop a novel fluorescence quenching method for mefenamic acid determination using Rhodamine 6G as a molecular probe. Comprehensive spectral characterization revealed that Rhodamine 6G exhibits characteristic absorption at 530 nm and emission at 555 nm, with systematic fluorescence quenching upon mefenamic acid addition while preserving the emission spectral profile. Mechanistic investigation through Stern-Volmer analysis, thermodynamic studies, and Job's method established static quenching via 1 : 1 ground-state complex formation with thermodynamic analysis revealing favorable binding driven by electrostatic and π-π interactions. Moreover, central composite design optimization was employed to systematically evaluate pH, Rhodamine 6G concentration, and reaction time, establishing optimal conditions that achieved 76.4% quenching efficiency. Additionally, ICH validation demonstrated excellent analytical performance including linearity over 0.1-4.0 μg mL-1 (r 2 = 0.9996), detection limit of 29.2 ng mL-1, accuracy of 98.48%, and precision <2% RSD. Method applications encompassed pharmaceutical formulations with statistical equivalence to reference HPLC methods and human plasma samples with recoveries of 96.30-102.21%. Furthermore, sustainability assessment revealed the superior environmental performance (AGREE score: 0.76 vs. 0.66, whiteness: 88.1% vs. 72.7%) compared to conventional HPLC methods. This work establishes a practical green alternative for routine mefenamic acid analysis in pharmaceutical quality control and therapeutic monitoring.
More Related Videos
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
11:24High Precision FRET at Single-molecule Level for Biomolecule Structure Determination
Published on: May 13, 2017