Related Experiment Video
Updated: Jan 17, 2026

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
Photon-counting detector computed tomography in thoracic oncology: revolutionizing tumor imaging through precision
Masahiro Yanagawa1, Midori Ueno1, Rintaro Ito2
1The University of Osaka Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Osaka, Japan.
Abstract:
Photon-counting detector computed tomography (PCD-CT) is an emerging imaging technology that promises to overcome the limitations of conventional energy-integrating detector (EID)-CT, particularly in thoracic oncology. This narrative review summarizes technical advances and clinical applications of PCD-CT in the thorax with emphasis on spatial resolution, dose-image-quality balance, and intrinsic spectral imaging, and it outlines practical implications relevant to thoracic oncology. A literature review of PubMed through May 31, 2025, was conducted using combinations of "photon counting," "computed tomography," "thoracic oncology," and "artificial intelligence." We screened the retrieved records and included studies with direct relevance to lung and mediastinal tumors, image quality, radiation dose, spectral/iodine imaging, or artificial intelligence-based reconstruction; case reports, editorials, and animal-only or purely methodological reports were excluded. PCD-CT demonstrated superior spatial resolution compared with EID-CT, enabling clearer visualization of fine pulmonary structures, such as bronchioles and subsolid nodules; slice thicknesses of approximately 0.4 mm and ex vivo resolvable structures approaching 0.11 mm have been reported. Across intraindividual clinical comparisons, radiation-dose reductions of 16%-43% have been achieved while maintaining or improving diagnostic image quality. Intrinsic spectral imaging enables accurate iodine mapping and low-keV virtual monoenergetic images and has shown quantitative advantages versus dual-energy CT in phantoms and early clinical work. Artificial intelligence-based deep-learning reconstruction and super-resolution can complement detector capabilities to reduce noise and stabilize fine-structure depiction without increasing dose. Potential reductions in contrast volume are biologically plausible given improved low-keV contrast-to-noise ratio, although clinical dose-finding data remain limited, and routine K-edge imaging has not yet translated to clinical thoracic practice. In conclusion, PCD-CT provides higher spatial and spectral fidelity at lower or comparable doses, supporting earlier and more precise tumor detection and characterization; future work should prioritize outcome-oriented trials, protocol harmonization, and implementation studies aligned with "Green Radiology".
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET