Characterization, Quantification and Compound-specific Isotopic Analysis of Pyrogenic Carbon Using Benzene Polycarboxylic Acids BPCA
Published on: May 16, 2016
Compound-specific carbon isotope analysis of perfluorocarboxylic acids (PFCAs) by gas chromatography-isotope ratio
Eduardo Di Marcantonio1, Orfan Shouakar-Stash2, Massimo Marchesi1
1Sapienza Università di Roma, Dipartimento di Scienze della Terra, Rome, Italy.
Abstract:
Per- and polyfluoroalkyl substances (PFAS) are synthetic chemicals widely used for their thermal and chemical resistance but are now of major environmental concern due to their persistence, bioaccumulation, and adverse health effects. Regulatory actions have been implemented globally, yet efforts to identify sources and degradation processes remain hindered by analytical limitations. Compound-Specific Isotope Analysis (CSIA) offers a promising approach for tracing PFAS sources and assessing their environmental transformation, but its application has been limited by the lack of suitable methods. This study presents the development and validation of a CSIA method for selected perfluorocarboxylic acids (PFCAs) and heptadecafluorooctane sulfonic acid (PFOS) using gas chromatography-Isotope Ratio Mass Spectrometry (GC-C-IRMS). An isobutyl-derivatization procedure was optimized to enhance compatibility with GC analysis, enabling successful isotope ratio measurements for perfluoroheptanoic acid (PFHpA), pentadecafluorooctanoic acid (PFOA), and nonadecafluorodecanoic acid (PFDA), with precision below ±0.5 ‰. In contrast, heptadecafluorooctane sulfonic acid (PFOS) could not be analyzed. Preliminary Elemental Analysis-IRMS (EA-IRMS) of standards from multiple suppliers revealed significant isotopic variability (up to 10 ‰), supporting the feasibility of isotopic fingerprinting for source attribution. Solid-phase microextraction (SPME) was employed for sample preparation, minimizing chromatographic interference. The method was successfully tested on real water samples spiked with PFCAs, demonstrating its potential for tracing PFCAs contamination in real-world contexts. This work lays the foundation for broader application of CSIA to PFCAs, providing a novel tool for environmental forensics and improved risk assessment.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
11:14Fatty Acid 13C Isotopologue Profiling Provides Insight into Trophic Carbon Transfer and Lipid Metabolism of Invertebrate Consumers
Published on: April 17, 2018
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Isotope Effect
Mass Spectrum: Interpretation
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...