A multi-modal diffusion model for noise reduction of particle number limited Monte Carlo dose calculation for carbon
Jueye Zhang1,2,3, Youfang Lai3, Haonan Feng3,4
1State Key Laboratory of Nuclear Physics and Technology, Institute of Heavy Ion Physics, Peking University School of Physics, Beijing, China.
Background:
The low computation efficiency impeded the broad application of Monte Carlo (MC) simulation to particle therapy. The existing deep learning (DL) methods for fast dose calculation lacked physics-based interpretability, hence, may introduce additional risks, especially for the more complex carbon ion radiotherapy.
Purpose:
To develop and validate a multi-modal diffusion model, Diff-MC, for noise reduction of particle number limited MC dose calculation, potentially supporting better optimization and faster online adaptation for carbon ion radiotherapy.
Methods:
By using multi-modal data such as CT images, dose maps using a low number of primary particles and beam parameters, and so forth, Diff-MC was developed to generate a dose map adaptively based on the beam state. To enable effective inter-modal interactions, a hybrid-fusion strategy was applied to integrate the data-level, feature-level, and decision-level fusion. The model was evaluated on a highly heterogeneous dataset, including 15 000 paired beamlet data cropped from 20 CTs for training and validating, 500 paired beamlet data cropped from other 5 CTs for testing, and 500 paired beamlet data cropped from another 100 CTs for generalizability test. All datasets encompassed various geometry and beamlet physics parameters such as energy distribution and number of primary particles, and so forth.
Results:
Using the MC simulation based on high number of primary particles as ground-truth, the Diff-MC achieved nearly linear acceleration and high accuracy of gamma passing rate up to 99.25% under the criteria of 3 mm, 3%, 10% cutoff. The performance was significantly higher (all ) than the UNet-based models (96.17%) and transformer-based models (97.81%). The accuracy achieved by Diff-MC in the generalizability test was 99.22%. The lateral dose, integral depth dose (IDD), and percentage depth dose (PDD) of Diff-MC were also more consistent with the ground-truth than that of conventional AI models.
Conclusions:
The proposed Diff-MC method displayed high efficiency and robustness in carbon ion dose calculation. By maintaining the physics features of MC, the results of Diff-MC were more interpretable and generalizable than the conventional AI models.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Radiation: Applications
The average...
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Biological Effects of Radiation
Dose Size and Dosing Frequency: Determination Methods
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...