Related Experiment Video
Updated: Jul 14, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Dosimetric and treatment efficiency comparison of lung SBRT using three different motion management strategies
Taliah Lansing1, Wendy Harris1, Mitchell Yu1
1Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA.
Purpose:
To compare the dosimetry and treatment efficiency of lung stereotactic body radiation therapy (SBRT) using the deep inspiration breath hold (DIBH), free breathing (FB), and respiratory gating (RG) strategies.
Methods And Materials:
308 lung SBRT patients with middle to lower zone lung tumors were included in this retrospective study. The prescriptions were 1000 cGy x 5 fractions, 1200 cGy x 4 fractions, or 1800 cGy x 3 fractions. They were all treated with a volumetric modulated arc therapy (VMAT) technique and 6 MV flattening filter free (FFF) beam on C-arm linear accelerators, but using different motion management strategies (151 DIBH, 136 FB, 21 RG). The lung dose (mean lung dose (MLD), V5, V20) and treatment time (on table, imaging & verification, delivery) of these patients were retrospectively collected for statistical comparison.
Results:
The average doses (MLD, V5, V20) to the ipsilateral lung were 408.2 cGy, 20.1 %, 5.7 % for the DIBH cohort, 569.8 cGy, 27.6 %, 8.4 % for the FB cohort, and 519.6 cGy, 23.5 %, 7.5 % for the RG patients. Correspondingly, the average time (on table/imaging & verification/delivery) for the three patient cohorts was 22.3/16.0/6.3 min, 13.6/10.5/3.1 min, and 22.7/14.6/8.1 min, respectively.
Conclusion:
Quantitative comparison of lung dose and treatment efficiency for three commonly used motion management strategies in lung SBRT is reported. While the relative advantages and disadvantages of these strategies are well recognized, our findings further confirm these differences and provide clinicians with quantitative data to support informed decision-making in clinical practice.
More Related Videos
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...