Related Experiment Video
Updated: Jan 17, 2026

Substernal Thyroid Biopsy Using Endobronchial Ultrasound-guided Transbronchial Needle Aspiration
Published on: November 10, 2014
Endobronchial ultrasound-guided sampling: diagnostic yield of needle biopsy and cryobiopsy in addition to needle
Jason Beattie1, Hamad Nasim1, Jacqueline Chen2
1Section of Interventional Pulmonology, Division of Thoracic Surgery and Interventional Pulmonology, Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States.
Rationale:
Endobronchial ultrasound (EBUS)-guided sampling for evaluation of benign conditions and lymphoma is not standardized. Sampling methods remain under study as new tools become available.
Methods:
We performed a single-center study with protocolized sampling and processing to evaluate the diagnostic yield of transbronchial needle aspiration (TBNA), Franseen needle biopsy (transbronchial needle biopsy [TBNB]), and cryobiopsy in patients with mediastinal and hilar abnormality with concern for sarcoid, lymphoma, or undifferentiated lymphadenopathy. Following TBNA, exploratory sampling was performed. A tract was created with a TBNB needle pass followed by cryobiopsy. Sampling was subsequently alternated for a total of 3 passes per tool. The primary outcome was diagnostic yield, using a strict criterion modeled from recent American Thoracic Society/American College of Chest Physicians guidelines. Secondary outcomes included procedural outcomes and pathologic assessment of TBNB and cryobiopsy samples.
Results:
Between January and December 2024, 56 nodes were sampled in 51 patients. Diagnostic yield per node was 86% (48/56). Regarding individual tools, the yield was 50% for TBNA, 73% for TBNB, and 82% for cryobiopsy (TBNA vs cryobiopsy, P = .0001; TBNA vs TBNB, P = .006; TBNB vs cryobiopsy, P = .13). In subgroup analysis, TBNB and cryobiopsy enhanced diagnostic yield in benign conditions (TBNA [59%], TBNB [88%], and cryobiopsy [100%]; TBNA vs cryobiopsy, P = .002; TBNA vs TBNB, P = .01; TBNB vs cryobiopsy, P = .11). For lymphoma, the diagnostic yield per node was 3/10 for TBNA, 5/10 for TBNB, and 6/10 for cryobiopsy (TBNA vs cryobiopsy, P = .001; TBNA vs TBNB, P = .1; TBNB vs cryobiopsy, P = .1). Upon pathology review, TBNB provided larger samples compared to cryobiopsy but TBNB samples contained a larger proportion of blood; these differences translated to similar resultant areas of diagnostic tissue for both tools. Sample usage for immunohistochemistry and special staining was higher for cryobiopsy (61%) vs TBNB (33%). Study sampling was feasible in all patients with a 2% complication rate (1 pneumothorax).
Conclusions:
Both TBNB and cryobiopsy enhance the diagnostic yield of EBUS-TBNA in benign conditions. Multiple passes with 3 biopsy tools at an individual lymph node is safe and feasible. Cryobiopsy provides superior sample quality relative to TBNB and superior yield vs TBNA in lymphoma.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description