Role of peri-deployment right ventricular paced-ECG in left bundle area pacing
Wen-De Tang1, Chiung-Ray Lu1, Mei-Yao Wu2
1Division of Cardiovascular Medicine, Department of Internal Medicine, China Medical University and Hospital, Taichung, Taiwan.
Background:
Left bundle area pacing (LBBAP) has emerged as a promising physiological pacing modality. The current technique for LBBAP lead implantation predominantly relies on the anatomy of the His bundle and right ventricular septum. While practical, this anatomical approach can lead to variations in lead polarity and QRS durations due to the relatively extensive target zone.
Objectives:
This study aims to investigate whether peri-deployment paced ECGs can effectively guide LBBAP and enhance left ventricular activation.
Methods:
We conducted a retrospective analysis of 41 patients (54 attempts) who underwent LBBAP between 1 September 2020 and 30 June 2021. We collected and analyzed demographic data, baseline ECGs, intraprocedural ECGs, and ventricular local electrograms. QRS patterns were categorized into five common types, R, Rs, rs, rS, and S, and were labeled from 1 to 5 for polarity analysis. In addition, we explored markers associated with achieving shorter QRS durations (<120 ms).
Results:
LBBAP was successfully achieved in 81.5% of the attempts. During the procedure, the paced QRS duration (QRSd) significantly decreased from 144.5 ± 22.6 ms-128.8 ± 22.9 ms (p < 0.001). Comparing lead polarity scores before and after deployment revealed a significant increase in leads I and aVL (lead I, 1.3 ± 0.9 vs. 1.6 ± 1.0, p = 0.002; lead aVL, 1.6 ± 1.0 vs. 2.1 ± 1.3, p = 0.002), while leads III and aVF showed a decrease (lead III, 3.9 ± 1.2 vs. 3.4 ± 1.5, p = 0.001; lead aVF, 3.1 ± 1.2 vs. 2.9 ± 1.3, p = 0.026). The polarity of leads II and aVR remained unchanged. In the subgroup with post-deployment QRSd shorter than 120 ms, although the Qr pattern in lead V1 was only numerically higher (95.2% vs. 81.8%, p = 0.310), the lead polarity scores were significantly higher in leads I and aVL and lower in leads III and aVF (p < 0.001). This group also had a significantly shorter left ventricular activation time (LVAT) (68.7 ± 13.0 ms vs. 98.4 ± 14.0 ms, p < 0.001). Univariate analysis revealed that a shorter pre-deployment paced QRSd and LVAT were associated with a narrower post-deployment QRSd. In addition, non-electrical factors such as female gender and left ventricular dilation were associated with higher post-deployment QRSd.
Conclusions:
Peri-deployment ECG assessment is a practical adjunct to anatomy-based LBBAP, providing real-time markers for optimal lead positioning. Specifically, an unaltered lead II axis and expected changes in the lead I/aVL and lead III/aVF axes can help guide the selection of the left bundle branch. Lower pre-deployment paced QRSd and LVAT, as well as a more rightward inferior axis after deployment, are associated with a shorter post-deployment QRSd.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
09:52Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
Published on: November 7, 2019
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiac Catheterization II: Right Heart Catheterization
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...