Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
From Wrist to Precision: Enhanced Atrial Flutter Detection with Modified Smartwatch Single-Lead Electrocardiogram
Yuval Avidan1, Amir Aker1,2, Razi Khoury1
1Department of Cardiology, Lady Davis Carmel Medical Center, Haifa, Israel.
Background:
Smartwatches, such as the Apple Watch (AW), are well-established tools for detecting atrial fibrillation (AF). We hypothesize that atrial flutter (AFL) is frequently misdiagnosed using traditional single-lead electrocardiogram configurations and that modified device positioning could substantially improve diagnostic accuracy.
Methods:
Standard smartwatch lead-I (AW-I) recordings were obtained from 75 patients, including 25 with AFL, 25 with AF, and 25 with sinus rhythm. Additionally, modified lead-II (AW-II) recordings were collected for all AFL cases, resulting in a total of 100 tracings. Twenty blinded physicians from 4 different specialties independently analyzed all recordings.
Results:
Physicians' ability to detect AFL using the AW-I lead was poor, with only 11.6% of cases correctly identified (P = 0.362). AFL was most often misdiagnosed as AF (55.6%), undetermined (21%), or sinus rhythm (11.8%). Diagnostic accuracy improved significantly with the AW-II lead, exceeding 80% among electrophysiologists, cardiologists, and primary care physicians (P = 0.001). Variable atrioventricular conduction was associated strongly with correct diagnosis exclusively through the AW-II lead (odds ratio 1.85, 95% confidence interval 1.14-3.0, P = 0.012).
Conclusions:
The standard lead-I configuration used by smartwatches is prone to misclassifying AF as AFL, particularly in the setting of variable conduction. A simple modification to lead-II positioning significantly enhances diagnostic accuracy. This adjustment may be especially valuable during post-pulmonary vein isolation surveillance and in broader clinical scenarios in which precise rhythm identification can influence therapeutic decision-making.
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Dysrhythmias V: Evaluating Dysrhythmias