Methods for Untargeted Analysis of Milk Metabolites: Influence of Extraction Method and Optimization of Separation
Daisy Wilkie1, Brad White1, Golnaz Heidari1,2
1Fonterra Research and Development Centre, Palmerston North 4472, New Zealand.
Background/Objectives:
Cow's milk is a complex food, and research into its metabolome can provide information useful in the study of animal health, farming practices, food safety and the adulteration of milk. Comparative interlaboratory metabolic analysis is hampered by the lack of standardized methods-a requirement addressed in this study.
Methods:
We studied the influence of the chromatography column and extraction solvent on the metabolites isolated during untargeted metabolomics.
Results:
After studying fifteen columns and four extraction solvents, it was determined that an HILIC column offered the best compromise between retention time and separation of metabolites. Each extraction solvent covered a different area of the metabolome, only overlapping with previously annotated compounds. Extraction mixtures containing methanol tend to give better recovery.
Conclusions:
The choice of extraction solvent was crucial when looking at the difference between samples, but if interest lies only in previously annotated compounds, then there is little difference between the solvents.
More Related Videos
11:25Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
Published on: July 11, 2014
11:17A Simple Fractionated Extraction Method for the Comprehensive Analysis of Metabolites, Lipids, and Proteins from a Single Sample
Published on: June 1, 2017
Related Concept Videos
Extraction: Advanced Methods
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...