The integration of DC networks including DC microgrids (DCMGs) into power systems is rapidly increasing. This is notably attributed to the distinctive fault current characteristics arising from inverter-based distributed generation resources in DCMGs, which differentiate them from conventional networks. As a result, the protection of DCMGs presents considerable challenges. Leveraging the recent strides in artificial intelligence, this paper introduces a novel multi-agent-based protection scheme for DC microgrids. Subsequently, three fault classification approaches are proposed in an intelligent protection scheme platform, employing diverse machine learning-based methods as a backup protection for fault detection and the main protection for fault location. The proposed protection scheme uses three main protection layers-namely, equipment, substation, and system-each endowed with specialized agents. In this way, the first and second fault classification approaches employ classifiers based on machine learning algorithms, such as Support Vector Machine (SVM) and Decision Tree (DT), to ascertain the microgrid status. Subsequent fault location is accomplished through various neural networks dedicated to the fault location. In the third approach, three Deep Neural Networks (DNNs) are proposed for fault classification, prompting the exclusion of classifiers from the substation layer due to the heightened training proficiency of DNNs. Intelligent Electronic Devices (IEDs) are placed at the beginning of the lines and send voltage and current information to the substation layer. Communication among agents and layers is performed by the IEC-61850 protocol. Comprehensive simulations and analyses are conducted using DIgSILENT, MATLAB, and Python (TensorFlow platform and Keras library) software. The findings underscore the efficacy of the proposed scheme and Fault Detection and Location (FDL) approaches, affirming their capability for precise fault classification and location determination.
Related Concept Videos
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Multi-input and Multi-variable systems
In the absence of...
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by: