A Framework to Evaluate Feasibility, Safety, and Accuracy of Wireless Sensors in the Neonatal Intensive Care Unit:
Eva Senechal1, Daniel Radeschi2, Emily Jeanne1
1Experimental Medicine Department, McGill University Health Center, Montreal, QC H3A 0G4, Canada.
Abstract:
Monitoring vital signs in the Neonatal Intensive Care Unit (NICU) typically relies on wired skin sensors, which can limit mobility, cause skin issues, and interfere with parent-infant bonding. Wireless sensors offer promising alternatives, but evaluations to date often emphasize accuracy alone, lack NICU-specific validation, and rarely use standardized frameworks. Our objective was to develop and apply a comprehensive framework for evaluating the feasibility, safety, and accuracy of wireless monitoring technologies using a wireless pulse oximeter, the Anne limb (Sibel Health, USA), in real-world NICU conditions. A prospective study was conducted on a diverse NICU population. A custom system enabled synchronized data recordings from both standard and wireless devices. Feasibility was assessed as signal coverage across a variety of daily care activities and during routine procedures. Safety was evaluated through skin assessments after extended wear. Accuracy was examined sample-by-sample and interpreted using the Clarke Error Grid for clinical relevance. The wireless oximeter device showed high feasibility with reliable Bluetooth connection across a range of patients and activities (median wireless PPG coverage = 100%, IQR: 99.85-100%). Skin assessments showed no significant adverse effects. Accuracy was strong overall (median bias 1.34%, 95% LoA -3.63 to 6.41), with most data points within clinically acceptable Clarke error grid zones A and B, though performance declined for infants on supplemental oxygen. This study presents a robust, multidimensional framework for evaluating wireless monitoring devices in NICUs and offers recommendations for future research design and reporting.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...