Related Experiment Video
Updated: Jan 16, 2026

Enhancing Efficiency and Radiolabeling Yields of Carbon-11 Radioligands for Clinical Research Using the Loop Method
Published on: December 20, 2024
Alternative production of Lead-203: Optimizing production, purification, and radiolabelling for enhanced theranostic
Nadia Audouin1, Héloïse Dufour1, Aurélien Vidal1
1GIP ARRONAX, 1 rue aronnax, CS10112, 44817, Saint-Herblain Cedex, France.
Introduction:
this study investigates the production of Lead-203 (203Pb) using a deuteron beam and demonstrates its application with DOTATATE for diagnostic imaging of neuroendocrine tumours (NETs) thanks to its γ-ray emissions well-suited for SPECT imaging. 203Pb presents a high potential in nuclear medicine, as it is the imaging counterpart of part of Lead-212 (212Pb), a radionuclide with an alpha-emitting decay chain used for targeted alpha therapy.
Methods:
Enriched Thallium-205 (205Tl) was electrodeposited onto a gold substrate using a custom-made PEEK cell, with a platinum rod as the auxiliary electrode. The electrodeposition was conducted at a controlled temperature and stirring speed, with reverse pulse potentials applied to obtain a smooth and dense deposit. The 205Tl deposit was then irradiated with deuteron beams at 31 MeV to produce 203Pb. Chemical separation was performed using two columns containing Pb resin. The first column (150 mg resin) was used to remove 205Tl for further recycling and the second column (60 mg resin) was employed to obtain 203Pb in 1 M ammonium acetate at pH 5 ensuring high purity and specific activity. Radiolabelling of DOTATATE with 203Pb was conducted in a modified acetate buffer, and the radiochemical purity and stability were assessed using HPLC and TLC. The stability of [203Pb]Pb-DOTATATE was evaluated over a period of up to 120 h.
Results:
the electrodeposition process, conducted over 8 h, yielded a reproducible 205Tl deposit with an average thickness of 37.7 ± 3.2 μm, which remained stable during irradiation. The chemical separation process achieved a 203Pb purity exceeding 99 % in 1 M ammonium acetate at pH 5, with a specific activity surpassing 3783 TBq/g for an integrated beam current of 175 μAh at calibration time (EOB + 32 h). The radiochemical separation yield during the process was 80.5 %. Radiolabelling of DOTATATE with 203Pb showed a high radiochemical purity (99.1 %) and a stability over 96 h, demonstrating the feasibility of using [203Pb]Pb-DOTATATE for clinical applications.
Conclusion:
Our results support the use of 203Pb produced using deuteron beam as valuable tools in the advancement of personalized nuclear medicine therapies. The high purity and specific activity of 203Pb, achieved through dual Pb resin purification process, along with its effective radiolabelling with DOTATATE at high yield and long stability, underscore its potential for clinical use in diagnostic imaging, especially in neuroendocrine tumours.
![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)