Related Experiment Video
Updated: Jan 16, 2026

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
Atomic Ordered Functionalization by Covalent and Noncovalent Interactions for Glycine Detection in Armchair Graphene
Manasa Bhat1, Kaustab Ghosh2,3, Ramachandran Gnanasekaran4
1Department of Physics, School of Advanced Sciences, Vellore Institute of Technology, Chennai Campus, Chennai, Tamil Nadu 600127, India.
Abstract:
This study investigates the covalent and noncovalent functionalization (CF and NCF) of glycine (Gly) on armchair graphene nanoribbons (AGNR42 and AGNR54) at different sites (bulk, single edge, and double edge) using density functional theory (DFT) at the B3LYP/6-311++G-(d,p) level. For covalent bonding, two different attachment modes of Gly (O and N sites) were considered. Key sensing parameters such as adsorption energy (E ad), band gap (E g), density of states (DOS), charge transfer, electrical conductivity, molecular electrostatic potential (MEP), sensitivity, and recovery time were analyzed. The results show that covalent bonding enhances sensitivity due to strong chemical attachment, while noncovalent bonding enables quicker recovery due to weak physical interactions. Although AGNR54 has a larger surface area, AGNR42 demonstrates better sensitivity with CF. The configurations, such as NCF-Gly-SEAGNR42, NCF-Gly-DEAGNR42, NCF-Gly-SEAGNR54, O-Gly-BFAGNR54, and N-Gly-BFAGNR54, exhibit fast recovery times of 1.599 × 10-12 s, 6.15 × 10-4 s, 76 s, 595 s, and 5.293 × 106 s, respectively. Among these, N-Gly-BFAGNR54, NCF-Gly-SEAGNR54, and O-Gly-BFAGNR54 exhibit intermediate sensing responses (0.223, 0.026, and 0.019, respectively) and acceptable recovery time. These findings further emphasize the relationship between sensitivity and reusability, where enhancing one often affects the other. The overall sensing performance is governed not only by the bonding type but also by the surface area, position of sites, adsorption site, adsorption energy, and the orientation of the analyte. Thus, the significant variation in adsorption and electronic properties of AGNRs reveals that atomic-order functionalization enhances the detection of Gly and may be considered a promising biosensor for Gly removal. This study also provides new evidence and deeper insights that advance the current understanding of GNR-based biosensing systems.
Related Concept Videos
Noncovalent Attractions in Biomolecules
Four types of noncovalent interactions are hydrogen bonds, van der Waals forces, ionic bonds, and hydrophobic interactions.
Hydrogen bonding results from the electrostatic attraction of a hydrogen atom covalently bonded to a strong-electronegative atom like oxygen,...
Noncovalent Attractions in Biomolecules
Valence Bond Theory

